Humax IR-5410Z+ manual Motorised system, GB37

Page 38

Motorised system

DiSEqC 1.2 User Instructions

If you have a DiSEqC 1.2 motorised system, then you can use the DiSEqC 1.2 functions available. The following instruction describes how to use the DiSEqC 1.2 functions to store the positions of the satellites and to search for the services(STAB Rotor Sat motor recommended).

1. Satellite Setting Menu Options

When DiSEqC Motorised System is Enabled in the Antenna Setting, a new menu is available for configuring the motor. This menu is called Satellite Setting and is accessed by pressing the OK button while the option Antenna Alternative is highlighted in the Manual Search menu.

The following options are available on the Satellite Setting menu.

Satellite Name

A selection of satellite names that can be used to identify a motor position. If the satellite name you require is not available, please use other. In installer mode the Satellite Name Reference refers to the 0 position of the motor.

Movement

In user mode this is used to fine-tune the position of the motor for better reception. In Installer mode this is used to search for the position of a satellite manually.

Motor Control

Search : Searches for services on the chosen transponder.

Goto

: Moves the motor to the stored position of the selected satellite name.

Store

:

Stores the current position of the motor for the selected satellite name.

Reset

:

Resets all stored positions of the motor relative to the 0 position. (Installer mode only)

DiSEqC Command Mode

Changes the current mode between Installer and User.

2. Setting your Receiver for DiSEqC 1.2

You must set your receiver up so that it is ready to use DiSEqC 1.2. To do so, do as follows

1.Press the MENU( )button, to display the Main Menu.

2.Select Service Searching option and press OK button, to display the Service Searching menu.

3.Select Antenna Setting option and press OK button, to display the Antenna Setting menu.

4.You must set up a separate antenna alternative for each satellite position required.

5.Select the name of the satellite you wish to use.

6.Select the correct LNB frequency for the LNB you are using.

7.Set the Motorised System to Enable using the buttons.

8.The option DiSEqC Input Selection should now be disabled.

This option is used for DiSEqC 1.0 and cannot be used in conjunction with DiSEqC 1.2.

Your receiver is now ready to use DiSEqC 1.2. To return to the Main Menu, use the EXIT button until you are at the Main Menu.

GB37

Image 38
Contents Digital Set-Top Box with Irdeto Embedded Contents Safety LiquidsGlossary Copyright & GlossaryCopyright Connect a Satellite antenna ReferenceConnect DiSEqC Loop ThroughSTB Connections Front PanelVCR Scart For the VCR Rear PanelRS-232C With Hi-Fi System TV onlyTV with VCR TV with VCR and Motorised SystemDiSEqC GB9 GB10 Remote Control Unit GB11GB12 GB13 Changing ServicesGuide of Functions Information BoxI-PlateSoundtrack Volume ControlGB14 SubtitleGuide of Main Menu GB15GB16 Simple Service ListAdvanced Service List Service Genre Service FavouriteService Network Service Alphabet OrderGB18 Now/Next modeWeekly mode GB19 Reserved modeQuick mode GB20 System SettingLanguage Setting Time Setting GB21Output Setting GB22Channel UHF TuningGB23 PAL StandardOther Setting GB24GB25 Service OrganisingOrganise TV Services Organise Favourite A~D To group the services into FavouritesGB26 To select the Favourite groupGB27 Organise Service GenreTo group the services into a Genre To select the GenreOrganise Networks Organise Radio ServicesGB28 GB29 Service SearchingAntenna Setting Antenna Alternative22KHz Tone GB30LNB Frequency DiSEqC InputGB31 Service Search OSDFound services OSD GB32 Manual SearchAdvanced Search LNB PowerGB33 Video PID/Audio PID/PCR PIDAutomatic Search Detail ModeGB34 Search TypeStatus Signal DetectionGB35 STB StatusVersion Information Conditional Accessfor Irdeto EmbeddedGB36 Smart card InformationMotorised system GB37GB38 Initial Satellite Position SearchGB39 To set the West LimitGB40 Moving to a pre-set SatelliteTroubleshooting Guide GB41GB42 Menu Map GB43GB44 Specification GB45Data In/Out GB46