Maxplus Industries HTS 2100S+ manual Antenna Setup, Committed/Uncommitted Select the DiSEqC port

Page 8

6.1 Getting Started

2) Antenna Setup

Press the MENU button to display the main menu.

Use CH

/ CHand VOL / VOL to move in the menu.

Press

on ‘Dish Setting’. The following window will appear. <Figure 6-2>

If you have a motorized dish, press

on ‘Motorized Setting’. < Figure 6-3>

Note : Enter a 4-Digit password if need arise. The default password is ‘0000’.

<Figure 6-2>

<Figure 6-3>

Select the item that you want to edit, and set its parameters as desired. <Dish Setting>

-LNB Power : Select among ON/OFF/13V/18V.

-LNB Type : Select among Single/Universal/OCS.

-LNB Freq : Set the frequency of the LNB oscillator.

-22KHz : When not AUTO, set the signal path from LNB or switch by selecting a control signal among 0/22KHz.

-DiSEqC switch : Select DiSEqC protocol among OFF/1.0/1.1 as appropriate for your configuration.

-Committed/Uncommitted : Select the DiSEqC port.

Select the item that you want to edit and set its parameters as desired. <Motorized Setting>

-Frequency : If the default TP frequency is not appropriate, you can select another TP frequency at which to check for signal.

-DiSEqC Motor : Select DiSEqC protocol among OFF/1.2/USALS as appropriate for your Motor.

6.1 Getting Started

(When the DiSEqC Motor parameter is set as 1.2)

-Move : You can move the dish to the West/East.

-Limit : If you want to set limits, press .

-Disable Limit : You can disable the East and West limits.

-Goto Center : Move the dish to the initial 0 position.

-Set East / West Limit : Move the dish East or West using VOL / VOL .

Press to set East or West limit.

(When the DiSEqC Motor parameter is set as USALS)

-Sat Degree : Satellite location.

-Antenna Position : Press .

-Goto Reference : Move the dish to the reference 0 position.

-Antenna Longitude : Your longitude at present.

-Antenna Latitude : Your latitude at present.

Note : You need to know what LNB you are using to correctly set the L.O. (local oscillator) frequency.

Note : You need to understand how your receiver is connected to properly set the 22KHz and DiSEqC.

When you are done, press the EXIT button.

12

13

Image 8
Contents USER’S Manual Contents Safety/Precautions SafetyMain Features IntroductionPrecautions AccessoriesPoints to Check before Use Satellite dishName Connector Function Controls/FunctionsFront Panel Rear PanelRemote controller How to Connect Menu Language SettingOperation Getting StartedAntenna Position Press Antenna SetupCommitted/Uncommitted Select the DiSEqC port Satellite Scan Auto Scan FigureChannel Selection Other Functions of the Remote Control Volume ControlV Output Settings System SettingTime Settings OSD Settings Security SettingsDatabase Reset CalculatorData Transfer Delete All Channels Erase all channelsChannels Set FavoritesEdit Channels Move ChannelsLock Channels Skip ChannelsEPG Electronic Program GuideDelete Channels Timer GamesTetris SokobanSystem Information Common InterfaceSnake CAM InitializingTroubleshooting Status of the CAMSpecifications

HTS 2100S+ specifications

Maxplus Industries has once again demonstrated its commitment to innovation and quality with the introduction of the HTS 2100S+, a cutting-edge solution designed for a multitude of applications across various industries. This advanced machine offers a unique blend of performance, efficiency, and user-friendly features that set it apart from its competitors.

At the core of the HTS 2100S+ is a state-of-the-art processing unit that enables high-speed operations without compromising on accuracy. The machine boasts a robust construction, ensuring durability even in the most demanding environments. Its sleek design allows for optimal space utilization, making it an ideal choice for companies looking to maximize their operational capacity without overwhelming their floor space.

One of the standout features of the HTS 2100S+ is its adaptive control technology. This innovative system enables the machine to automatically adjust its operations based on real-time data, ensuring consistent output quality while minimizing energy consumption. Users can expect significant reductions in operational costs, thanks to this intelligent energy management system that not only enhances productivity but also contributes to sustainability efforts.

The user interface of the HTS 2100S+ is another highlight, featuring an intuitive touchscreen display that allows for easy navigation and control. Operators can quickly adjust settings, monitor performance, and access comprehensive reporting tools, streamlining the entire workflow process. Additionally, the machine supports remote monitoring and diagnostics, enabling technicians to troubleshoot issues and perform maintenance without the need for on-site visits.

Furthermore, the HTS 2100S+ is compatible with various industry-standard software and integrates seamlessly with existing systems. This flexibility ensures that businesses can adopt the machine without overhauling their current workflows or incurring additional costs.

In terms of safety, Maxplus Industries has equipped the HTS 2100S+ with advanced features such as emergency stop buttons, protective enclosures, and comprehensive safety protocols that adhere to international standards. These measures not only protect operators but also enhance overall workplace safety.

Overall, the Maxplus Industries HTS 2100S+ stands out as a versatile, efficient, and user-friendly solution that caters to a range of industrial needs. By emphasizing performance, adaptability, and safety, Maxplus Industries has once again reinforced its position as a leader in the manufacturing sector. Whether for production, assembly, or complex material handling tasks, the HTS 2100S+ is poised to elevate operational efficiency and drive success for businesses in diverse industries.