Telex instruction sheet Connections, Fuses and Indicators, ACS-101 Rear View

Page 2

Connections, Fuses and Indicators

1

 

 

 

 

 

 

RadioComTM

ACS-101

 

by Telex

UHF Antenna Splitter/Combiner

 

 

 

 

 

 

 

POWER - GREEN

 

 

OVERHEAT - RED

 

 

 

 

 

Figure 1 ACS-101 Front View

1.Power/Overheat Light - Green - The unit has power.

Red - The unit has overheated and the combiner amplifiers have shutdown. There is a sensor on the combiner amplifier heatsink that senses if the heat rises above 75º C (167 F).

78

4

2

FUSE

DC OUT

5A SLOW BLOW

12V 5A

 

 

 

 

 

 

 

TRANSMIT

 

RECEIVE

RECEIVE

FUSE

5A SLOW BLOW

ANTENNA

 

 

TRANSMIT ANTENNA

DC OUT

12V 5A

4

3

5

6

2

Figure 2

ACS-101 Rear View

2.DC Outlet Fuses - 5 Amp, SlowBlow, 250 VDC. Size is 3AG.

3.IEC Power Inlet with Fuse - IEC-320 power inlet with a 10 Amp, 250 VDC Fuse. Size is 5mm by 20mm.

4.DC Power Output Jacks - Threaded 5.5mm x 2.1mm Jacks. 12 VDC up to 5 Amps is available at each jack.

5.Receive Antenna Jack - This TNC female connector is where the receive antenna connects.

6.Receive Splitter Jacks - These ten TNC Female connectors are the outputs for the receive signals. NOTE: All unused jacks should be terminated with 50 Ohm loads (See accessories listed at the end of this document).

7.Transmit Combiner Jacks - These ten TNC female connectors are the inputs for the transmitters.

8.Transmit Antenna Jack - This TNC female connector is where the transmit antenna connects.

-2-

Image 2
Contents ACS-101 Product Features General DescriptionConnections, Fuses and Indicators ACS-101 Rear ViewSystem Configuration System ConfigurationAntenna Requirements ALP-450 ALP-600 Wave AntennaCoax Cable Antenna Placement For Optimum Range and Rack MountingRack Mounting Rack Mount BracketsTP-2 50 OHM/TNC dummy load Order No ALP-450Order No AB-2