Miscellaneous
External Control Device Setup
-Connect the
How to connect external control equipment
•Connect the serial port of the control device to the
•
•The Monitor remote control and front panel controls (except main power) will not be functional if the Monitor is controlled by a PC computer or other external device.
Type of connector; D-Sub 9-pin male
No. Pin name
1No connection
2RXD (Receive data)
3TXD (Transmit data)
4DTR (DTE side ready)
5GND
6DSR (DCE side ready)
7RTS (Ready to send)
8CTS (Clear to send)
9No Connection
RS-232C configurations
(Standard
PC | PDP |
1
5
9
6
(Not standard)
PCPDP
RXD | 2 |
| 3 |
| TXD |
|
| ||||
TXD | 3 |
| 2 |
| RXD |
|
| ||||
GND | 5 |
| 5 |
| GND |
|
| ||||
DTR | 4 |
| 6 |
| DSR |
|
| ||||
DSR | 6 |
| 4 |
| DTR |
|
| ||||
RTS | 7 |
| 8 |
| CTS |
|
| ||||
CTS | 8 |
| 7 |
| RTS |
|
|
|
|
|
|
|
|
RXD | 2 |
TXD | 3 |
GND | 5 |
DTR | 4 |
DSR | 6 |
RTS | 7 |
CTS | 8 |
|
|
3TXD
2RXD
5GND
4DTR
6DSR
7RTS
8CTS