Installation Instructions |
| RMF2/RLF2/RXF2 | |
Assembly And Installation |
|
| |
Install Wall Plate to Wall - Wood Studs | 2 | ||
|
|
| |
|
|
| x 4 or 6 |
| WARNING: Failure to provide adequate structural strength | 3 | |
| for this component can result in serious personal injury or | ||
|
| ||
| damage to equipment! It is the installer’s responsibility to |
| |
| make sure the structure to which this component is attached |
| |
| can support five times the combined weight of all equipment. |
| |
| Reinforce the structure as required before installing the |
| |
| component. The wall to which the mount is being attached |
| |
| may have a maximum drywall thickness of 5/8" (1.6cm). Do |
| |
| not install drywall anchors into the seam between drywall |
| |
| pieces. |
|
|
1. | Unfold wall plate (A) to prepare it for mounting to wall. (See |
| |
| Figure 1) |
|
|
|
|
| Figure 2 |
| 1 | (A) | 2 x 24" |
|
| ||
|
| 2 x 16" | |
|
|
| |
|
| 1 |
|
| Figure 1 |
| 3 x 16" |
|
|
| |
2. Level wall plate (A) and mark locations of pilot holes.(See | CENTER | ||
| Figure 2) |
| LINE |
|
|
| |
NOTE: The RMF2 must be installed on two 16" studs. The |
| ||
| RLF2 can be installed on 16" studs (inner holes) or 24" |
| |
| studs (outer holes). For the RXF2, it can be mounted | Figure 3 | |
| over two or three 16" studs or two 24" studs. If | ||
|
| ||
| mounting to three 16" studs, it must be mounted to all | 4. Install 5/16 x 2 1/2" hex head cap screws (C) through four | |
| three studs using the outer holes and center holes. | ||
| flat washers (D), wall plate (A) and into wood studs. (See | ||
| (See Figures 2 and 3) All studs must be 2"x4". | Figure 4) |
NOTE: The vertical center of the display will be even with the center line indicated on the labels located directly below each hinge. Keep this in mind when determining mounting location. (See Figure 3)
3.Drill 7/32" (5.5mm) diameter pilot holes into wood studs at marked locations. (See Figure 2)
| (D) x 4 or 6 |
|
4 | (C) x 4 or 6 | (A) |
Figure 4