Install Wall Plate to Wall - Wood Studs

2

 

 

 

 

 

 

x 4 or 6

 

WARNING: Failure to provide adequate structural strength

3

 

for this component can result in serious personal injury or

 

 

 

damage to equipment! It is the installer’s responsibility to

 

 

make sure the structure to which this component is attached

 

 

can support five times the combined weight of all equipment.

 

 

Reinforce the structure as required before installing the

 

 

component. The wall to which the mount is being attached

 

 

may have a maximum drywall thickness of 5/8" (1.6cm). Do

 

 

not install drywall anchors into the seam between drywall

 

 

pieces.

 

 

1.

Unfold wall plate (A) to prepare it for mounting to wall. (See

 

 

Figure 1)

 

 

 

 

 

Figure 2

 

1

(A)

2 x 24"

 

 

 

 

2 x 16"

 

 

 

 

 

1

 

 

Figure 1

 

3 x 16"

 

 

 

2. Level wall plate (A) and mark locations of pilot holes.(See

CENTER

 

Figure 2)

 

LINE

 

 

 

NOTE: The RMF2 must be installed on two 16" studs. The

 

 

RLF2 can be installed on 16" studs (inner holes) or 24"

 

 

studs (outer holes). For the RXF2, it can be mounted

Figure 3

 

over two or three 16" studs or two 24" studs. If

 

 

 

mounting to three 16" studs, it must be mounted to all

4. Install 5/16 x 2 1/2" hex head cap screws (C) through four

 

three studs using the outer holes and center holes.

 

flat washers (D), wall plate (A) and into wood studs. (See

 

(See Figures 2 and 3) All studs must be 2"x4".

Figure 4)

NOTE: The vertical center of the display will be even with the center line indicated on the labels located directly below each hinge. Keep this in mind when determining mounting location. (See Figure 3)

3.Drill 7/32" (5.5mm) diameter pilot holes into wood studs at marked locations. (See Figure 2)

 

(D) x 4 or 6

 

4

(C) x 4 or 6

(A)

Figure 4

7

Image 7
Contents RMF2/RLF2/RXF2 Disclaimer Important Safety InstructionsDimensions RLF2 Dimensions RMF2 Dimensions RXF2 By Hand Optional Parts Tools Required for InstallationFor this component can result in serious personal injury or Concrete Block Install Wall Plate to Wall Concrete orRecessed holes or extra depth needed Install Brackets to DisplayInstall Display to Wall Plate Views from left side USA/International