Xantech CC12 installation instructions Remote Relay Module, Features and Specifications

Page 1

INSTALLATION INSTRUCTIONS

CC12

REMOTE RELAY MODULE

The CC12, Fig. 1, is an IR Remote Controlled Double Pole Double Throw Relay Module. It provides dry contact closures to satisfy a variety of uses, such as activation of screen drops, projector lifts, etc. The switching is accomplished by way of infrared commands originating from a Xantech RC68+ Programmer (or RC68 Programmer). It can also be switched by a DC voltage applied between the CI (control input) and GND terminals. The RC68+ commands are "taught" to learning devices and passed to the IR IN, and GND input terminals of the CC12 signal input terminals via Xantech IR Receivers, Keypads and Connecting Blocks.

CODE

7

0

1

 

CC12

 

SUB-

6

 

2

 

REMOTE RELAY MODULE

GROUP

5

4

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N/C

 

 

 

IR IN

 

 

1

 

 

 

CI

OFF = N/C

N/O

 

 

 

 

 

 

 

GND

 

ON = N/O

N/C

 

 

 

 

 

 

 

 

+12VDC

 

2

 

 

 

 

 

 

N/O

IR CONFIRM

Fig. 1 The CC12

FEATURES AND SPECIFICATIONS

One 6-terminal plug-in connector to make connection to the internal DPDT relay.

5 Amp/30V DC relay contact rating.

4-terminal IR input (S = IR Signal, CI = Control Input, G = Gnd, V = +12V) for connection of Xantech IR Receivers, Smart Pads, Connecting Blocks and other devices.

All plug-in connectors accept wire sizes from 24 to 12 gauge.

IR CONFIRM LED goes on only when an RC68+ (or RC68) IR command signal activates unit.

LED turns ON when N/O (normally open) contacts are closed and goes OFF when N/C (normally closed) contacts are closed.

Four RC68+ IR commands permit Pair, Toggle, and Momentary operation of the switching relay.

IR activated ON condition (N/O contacts closed) goes OFF if power is interrupted.

+3V to +30V DC 1 mA applied to CI terminal will switch unit, instead of IR, if desired.

Factory preset Group Code number: 50.

CODE SUB-GROUPswitch allows a choice of 8 different groups of the four RC68++ commands that operate the CC12. This prevents mutual interaction in common IR systems when using more than one CC12 Also, internal E2 PROM can be set to different code groups, allowing up to 240 different IR code combinations if the system uses more than eight CC12's or in combination with SR21's.

Power: +12V DC @ 50 mA. Use the 781RG Power Supply for each CC12. If IR receivers or keypads are used on the same 12V line, use the 782-00 Power Supply.

Flanges, plus supplied screws, permits easy mounting to flat surfaces.

Dimensions: 5-1/4" x 2-3/8" x 1-7/8".

1

Remote Control Switchers

Image 1
Contents Remote Relay Module Features and SpecificationsApplicable RC68+ Button Descriptions RC68+ Programmer / Remote Control780-80 782-00 InstallationPair OFF command UP