INSTALLATION INSTRUCTIONS
CC12
REMOTE RELAY MODULE
The CC12, Fig. 1, is an IR Remote Controlled Double Pole Double Throw Relay Module. It provides dry contact closures to satisfy a variety of uses, such as activation of screen drops, projector lifts, etc. The switching is accomplished by way of infrared commands originating from a Xantech RC68+ Programmer (or RC68 Programmer). It can also be switched by a DC voltage applied between the CI (control input) and GND terminals. The RC68+ commands are "taught" to learning devices and passed to the IR IN, and GND input terminals of the CC12 signal input terminals via Xantech IR Receivers, Keypads and Connecting Blocks.
CODE | 7 | 0 | 1 |
| CC12 |
|
SUB- | 6 |
| 2 |
| REMOTE RELAY MODULE | |
GROUP | 5 | 4 | 3 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| N/C |
|
|
| IR IN |
|
| 1 |
|
|
| CI | OFF = N/C | N/O | |
|
|
|
| |||
|
|
| GND |
| ON = N/O | N/C |
|
|
|
|
| ||
|
|
| +12VDC |
| 2 | |
|
|
|
|
|
| N/O |
IR CONFIRM
Fig. 1 The CC12
FEATURES AND SPECIFICATIONS
•One
•5 Amp/30V DC relay contact rating.
•
•All
•IR CONFIRM LED goes on only when an RC68+ (or RC68) IR command signal activates unit.
•LED turns ON when N/O (normally open) contacts are closed and goes OFF when N/C (normally closed) contacts are closed.
•Four RC68+ IR commands permit Pair, Toggle, and Momentary operation of the switching relay.
•IR activated ON condition (N/O contacts closed) goes OFF if power is interrupted.
•+3V to +30V DC 1 mA applied to CI terminal will switch unit, instead of IR, if desired.
•Factory preset Group Code number: 50.
•CODE
•Power: +12V DC @ 50 mA. Use the 781RG Power Supply for each CC12. If IR receivers or keypads are used on the same 12V line, use the
•Flanges, plus supplied screws, permits easy mounting to flat surfaces.
•Dimensions:
1