Xantech CC12 installation instructions Installation, 780-80 782-00

Page 3

INSTALLATION

The CC12 can be used in any application that requires dry switch closures activated by IR commands or by a DC control voltage; up to the capacity of the DPDT 5A/30V DC relay. Some of the more likely applications would be to activate video projector lifts, screen drops, drape pulls, etc., in home automation systems. Fig. 3 is a simple example of a screen drop application.

780-80

 

782-00

 

 

Power

 

"J" Box

 

Supply

 

IR Receiver

To 120 V AC

 

 

(unswitched)

 

 

 

+12VDC

GND STATUS IR OUT

4-Conductor Cable

(Unshielded OK)

 

 

 

(To +12V System

 

 

 

Hand Held

Status Voltage,

Learning

if desired).

Remote

 

789-44

To Emitters on Other

Connecting Block

Controlled Equipment

12VDC

CONNECTINGBLOCK

789-44

EMITTERS

IR RCVR

+12 VDC

 

 

 

GND

 

 

 

STATUS

 

 

 

IR IN

 

 

 

CC12

Remote Relay Module

CODE

7

0

1

 

CC12

 

SUB-

6

 

2

 

REMOTE RELAY MODULE

GROUP

5

4

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N/C

 

 

 

IR IN

 

 

1

 

 

 

CI

OFF = N/C

N/O

 

 

 

 

 

 

 

GND

 

ON = N/O

N/C

 

 

 

 

 

 

 

 

+12VDC

 

2

 

 

 

 

 

 

N/O

IR CONFIRM

PROJECTION

SCREEN

CONTROLLER

MOMENTARY

UP

GND

DOWN

Fig. 3 Using a CC12 to Activate a Projector Screen Drop

Fig. 3 assumes that the projector screen controller can be configured to operate with a momentary switch closure action. That is, a momentary closure and release at its control terminals will cause the screen to drop to its fully extended position. A second momentary closure will cause it to retract to its fully withdrawn position.

You would then program one button on the Handheld Learning Remote with the MOMENTARY(MMT) command from the RC68+ (or RC68) Programmer. Refer to Fig. 2.

A 780-80 "J" box IR Receiver is shown for IR control of the system. Any of the other Xantech IR Receivers or keypads could also be used, depending on your system and aesthetic requirements. The STATUS LED indicator in the 780-80 can be driven by a +12V System Status (ON/OFF) voltage, such as from an adapter plugged into the Switched AC outlet on the system A/V receiver.

The 782-00 powers the IR receiver as well as the CC12 through the 789-44 Connecting Block.

Fig. 4 illustrates how both a screen and a projector lift can be operated at the same time.

Since the CC12 incorporates a DPDT relay, we can utilize the other half of the relay to perform dual operations, such as this, provided each operation can be carried out simultaneously.

Remote Control

780-80

 

782-00

 

 

Power

 

"J" Box

 

Supply

 

IR Receiver

To 120 V AC

 

 

(unswitched)

 

 

 

+12VDC

GND STATUS IR OUT

4-Conductor Cable

(Unshielded OK)

Hand Held

(To +12V System

Status Voltage,

Learning

if desired).

Remote

 

789-44

To Emitters on Other

Connecting Block

Controlled Equipment

12VDC

CONNECTINGBLOCK

789-44

EMITTERS

IR RCVR

+12 VDC

 

 

 

GND

 

 

 

STATUS

 

 

 

IR IN

 

 

 

CC12

Remote Relay Module

CODE

7

0

1

 

CC12

 

SUB-

6

 

2

 

REMOTE RELAY MODULE

GROUP

5

4

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N/C

 

 

 

IR IN

 

 

1

 

 

 

CI

OFF = N/C

N/O

 

 

 

 

 

 

 

GND

 

ON = N/O

N/C

 

 

 

 

 

 

 

 

+12VDC

 

2

 

 

 

 

 

 

N/O

IR CONFIRM

PROJECTION

SCREEN

CONTROLLER

MOMENTARY

UP

GND

DOWN

VIDEO PROJECTOR

LIFT CONTROLLER

MOMENTARY

UP

GND

DOWN

Switchers

Fig. 4

Simultaneous Operation of a Screen and Projector Lift Using a CC12

 

 

 

 

 

 

 

 

 

 

 

3

 

CC12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 3
Contents Remote Relay Module Features and SpecificationsApplicable RC68+ Button Descriptions RC68+ Programmer / Remote Control780-80 782-00 InstallationPair OFF command UP