Hunter Fan 81005, 81002 manual Preventative Maintenance

Page 2

W a r n i n g

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty.

2.Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhaust- ing of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards, such as those published by the National Fire Prevention

Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.

7.Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.

8.Install fan at least 5 feet (1.52 m) above the floor.

9.Never place a switch where it can be reached from a tub or shower.

10.This unit must be grounded.

11.For supply connection, use wires suitable for at least 90˚ C (194˚ F).

C A U T I O N

1.For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials.

2.To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further information and requirements.

W a r n i n g

DISCONNECT

ELECTRIC

POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screw- driver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

2

41938-01 3/29/2006

05-HF-024_EngS_3.29.06.indd 2

3/29/06 7:25:13 PM

Image 2
Contents Installation I d e Preventative Maintenance Before Installation X2 D05-HF-024EngS3.29.06.indd A11 New ConstructionA14 A15A21 A22 A18A19 B13 B11B12 B15B19 B16B17 B18 B20Attaching the Grille B22B23 Connect wiring harness. do not Allow the Fixture to Trouble Shooting SolutionWarranty Limited WarrantyFrisco Avenue, Memphis, Tennessee Desde Í a S t a l a c i ó nPrecaución Antes de la instalación Verifique todos los05-HF-024Sp3.29.06.indd Escoja la opción de instalación Construcción nuevaConecte los alambres como se muestra A21 Vaya al pasoConstrucción existente B17 En la página 24 para fijar la rejilla Fijación de la rejillaDE Iluminación Cuelgue DEL Mazo DE Cables Solución de problemas SoluciónGarantía Garantía LimitadaFrisco Avenue, Memphis, Tennessee Impreso en China
Related manuals
Manual 26 pages 33.48 Kb

81002, 81005 specifications

The Hunter Fan 81005 and 81002 are two distinguished models from Hunter Fan Company, a brand renowned for its innovation and commitment to quality in the ceiling fan industry. Both of these models showcase Hunter's dedication to combining aesthetics with functionality, making them suitable for various home decor styles and climates.

The Hunter Fan 81005, also known as the Hunter Dempsey, is designed with a modern vibe that seamlessly fits contemporary settings. One of its notable features is the integrated LED light fixture, which provides efficient and bright illumination. The light is dimmable, allowing users to customize their ambiance based on preference and occasion. The Dempsey also includes a 54-inch blade span, providing optimal air circulation for medium to large-sized rooms.

One of the key technologies in the 81005 is its whisper-quiet motor, ensuring that the fan operates silently even on the highest speed. This feature enhances comfort without the disruption of noise, making it ideal for bedrooms and living areas alike. The fan comes with three blades that are designed for maximum airflow, improving energy efficiency. Additionally, the Hunter Dempsey is equipped with a three-speed pull chain control, allowing you to switch easily between settings for personalized comfort.

In contrast, the Hunter Fan 81002, also known as the Hunter Cassius, presents a more industrial design with clean lines and a rustic finish. It's built with an energy-efficient motor, which operates quietly and helps to lower electricity bills, making it environmentally friendly without sacrificing performance. With a 52-inch blade span, it can cater to spaces of similar sizes as the 81005, ensuring powerful airflow where it's needed most.

The 81002 also features a reversible motor, allowing users to change the direction of the blades depending on the season. In summer, the fan can create a cool breeze by running in a counterclockwise direction, while in winter, the reverse setting helps circulate warm air, providing year-round usability.

Both models showcase Hunter Fan Company's commitment to superior craftsmanship and design, featuring materials that not only last but also enhance the aesthetic appeal of any room. Their adaptability to various environments and seasons makes them valuable investments for those seeking comfort and style in their living spaces. Whether you opt for the modern flair of the Hunter Dempsey or the industrial charm of the Cassius, both fan models represent the perfect blend of form and function that Hunter is known for.