Console Mode

Making Hardware Connections

Default Mode

When Default Mode is selected and the server properties are Updated (Saved) all the configuration settings return to their default values.

Note:

Refer to Chapter 5 for details on Serial Server Configuration settings.

See Chapter 12 for Serial Server default parameters.

Console Mode

In Console Mode the Configuration Menu can be accessed from a PC by connecting its RS-232 serial port to the ESP901 serial port or ESP902 Serial Port 1. Since the computer is a DTE device, and the serial ports are configured as DTEs (with DB-9M connectors), a null modem crossover cable must be used.

In Console Mode the default serial port settings are: 9600 baud, 8 data bits, No parity, and 1 stop bit. From Windows, HyperTerminal with VT100 terminal emulation can be used for

configuration.

Note:

Refer to Chapter 9 for details on Console Mode

Upgrade Mode

In Upgrade Mode firmware can be uploaded from a PC via its serial port to the ESP901 serial port or ESP902 Serial Port 1. Upgrading also can be accomplished via the network connection, using the ESP Manager software and a virtual COM port.

Note:

Refer to Chapter 8 for details on Upgrade Mode

RS-232 Mode

In RS-232 Mode the currently selected serial port is configured as an RS-232 interface supporting eight RS-232 signal lines plus Signal Ground and is configured as a DTE, like a computer. Signals are single ended and referenced to Ground. To use handshaking, Flow Control must be set to RTS/CTS during Configuration.

Note:

Refer to Appendix A for RS-232 connection pin-outs.

Manual Documentation Number: ESP901-902-3704

Chapter 2

13

Making Hardware Connections

RS-422 Mode

In RS-422 Mode the currently selected serial port is configured as an RS-422 interface supporting four RS-422 signal channels with full duplex operation for Receive, Transmit, RTS (Request To Send) and CTS (Clear To Send). The data lines are differential pairs (A & B) in which the B line is positive relative to the A line in the idle (mark) state. Ground provides a common mode reference. To use handshaking, Flow Control must be set to RTS/CTS during configuration.

Note:

Refer to Appendix B RS-422 connection pin-outs.

RS-485 Mode

In RS-485 Mode the currently selected port is configured as an RS-485 interface supporting transmit (TX) and receive (RX) signal channels using 2-wire, half-duplex operation. The data lines are differential with the Data B line positive relative to Data A in the idle (mark) state. Ground provides a common mode reference.

Note:

Refer to Appendix C for RS-485 connection pin-outs.

RS-485 Receiver Biasing

RS-485 Receiver Biasing can be implemented from the Serial Server if the network does not supply it. Remove the two side-cover screws of the Serial Server, slide the cover off and re-position the bias jumpers (shown open in the figure below) to enable biasing (shorting).

Figure 10. Internal Setting to Select RS-485 Bias

Note:

(For more information on RS-485 Receiver Biasing, see B&B Electronics RS-422/485 Application Note available at www.bb- elec.com)

14

Chapter 2

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

Image 12
Contents Multi-Interface Ethernet Serial Servers International Headquarters Manual Documentation Number ESP901-902-3704m Table of Contents Using Console Mode Features IntroductionDirect IP Mode Virtual COM ModePaired Mode Communication ModesHardware Setup Software InstallationSerial Server Configuration Serial Server Quick Start GuideInstall Virtual COM Ports on PC Check CommunicationsPackage Checklist ESP901/ESP902 Connections, Indicators and Reset SwitchMaking the Hardware Connections DIP Switches Serial Server/Port Operational ModesSerial Ports Console Mode Upgrade ModeRS-232 Mode RS-422 ModeSerial Server Serial Port Connector Pin-outs DTEInstalling the Vlinx ESP Software Software InstallationAutomatic Installation Manual InstallationUpdating an Existing Installation Opening the ESP ManagerUsing ESP Manager Hardware SetupSoftware Setup Software Overview MenusSearch for Servers Server Icons PaneSerial Server / Virtual COM Lists Status BarConfigure Server Properties Search Vlinx ESP Dialogue BoxRestarting Dialogue Box Configuring the Serial Server Properties PasswordDescription of the Server Properties Server NameIP Address NetmaskGateway MAC AddressSerial Timeout TCP Alive TimeoutConnection Mode Flow ControlSerial Port Mode Update/SavePort Status TCP/UDP PortFollowing dialogue box will appear Web Server Installing Virtual COM Ports Virtual COM Port InstallationMatching the Serial Server and Virtual COM Port Settings Windows Logo Testing WindowVlinx ESP COM3 Properties Window Removing the Virtual COM Port using Device Manager Removing Virtual COM PortsRemoving the Virtual COM port with ESP Manager Control Panel Window Upgrading the Serial Server Firmware Downloading the FirmwareUpgrading Via ESP Manager Preparing the SoftwareUsing Console Mode Console Mode SetupNavigating the Configuration Menus Using a Password Saving and Restarting the ConfigurationUsing the WEB Server Setting Server PropertiesWeb Server Operation Using Telnet Configuration Using TelnetNavigating the Configuration Menu Telnet Configuration Screens Technical Data ESP901 and ESP902Dhcp Serial Server DB-9 Pin-outs in RS-232 Mode RS-232 Straight-through Cable ConnectionsRS-232 Crossover null modem Cable Connections RS-232 Crossover DB-9 to DB-25 Conversion Connections RS-232 DTE Loopback ConnectionsSerial Server DB-9 Pin-outs in RS-422 Mode Appendix B RS-422 ConnectionsLoopback Connections for RS-422 Serial Server DB-9 Pin-out in RS-485 Mode Appendix C RS-485 ConnectionsStandard Ethernet Cable RJ-45 Pin-out Crossover Ethernet Cable RJ-45 Pin-outElectronics September

ESP902E, ESP902, ESP901E specifications

B&B Electronics offers a series of industrial-grade Ethernet serial servers known as the ESP901E, ESP902, and ESP902E. These devices are specifically designed to connect serial devices to an Ethernet network seamlessly, enabling effective communication and data transfer across various applications.

The ESP901E is engineered for single serial port applications, providing an easy and effective way to connect a serial device to a network. It supports various serial communication protocols, including RS-232, RS-422, and RS-485, making it versatile for a range of devices. One of its standout features is the ability to support 10/100 Mbps Ethernet connectivity, ensuring a reliable and high-speed network connection. Additionally, the ESP901E supports various network protocols, including TCP/IP and UDP, allowing users to integrate the device easily into their existing network infrastructure.

Moving to the ESP902, this model provides dual serial port capabilities, making it ideal for applications requiring the connection of multiple devices. Like the ESP901E, it supports common serial interfaces and offers the same 10/100 Mbps Ethernet connectivity. This flexibility enables it to cater to more complex systems where multiple serial devices need to be integrated into a single network environment. Furthermore, the ESP902 is equipped with features such as automatic baud rate detection, making configuration straightforward and reducing installation time.

The ESP902E enhances the capabilities of the ESP902 with additional features such as enhanced security protocols. It includes support for SSL and SSH, ensuring secure data transmission across the network. This added security layer is crucial for applications that handle sensitive information or require secure communication channels. The ESP902E maintains the user-friendly nature of its predecessors while integrating more advanced features suitable for modern industrial applications.

All three models boast rugged designs suitable for harsh environments, making them perfect for industrial applications without compromising performance. With an extensive operating temperature range and robust housing, these devices can withstand the rigors of factory floors and outdoor installations.

Overall, the ESP901E, ESP902, and ESP902E from B&B Electronics collectively serve to bridge the gap between serial communications and Ethernet networks, supporting various industrial applications while ensuring seamless integration, versatility, and security. Whether for simple single-port connections or more complex multi-port setups, these devices are designed to meet diverse connectivity needs with efficiency and reliability.