B&B Electronics ESP901E, ESP902E manual RS-232 Crossover DB-9 to DB-25 Conversion Connections

Page 42

RS-232 Connections

RS-232 Straight-through DB-9 to DB-25 Conversion Connections

Figure 63. DB-9 to DB-25 Straight-through Cable Connections

RS-232 Crossover DB-9 to DB-25 Conversion Connections

RS-232 Connections

RS-232 DTE Loopback Connections

Figure 65. Loopback Connections for RS-232

For Transmit and Receive loopback, connect only those lines.

When Flow Control setting on the Serial Server is set for RTS/CTS, those lines must be looped. Usually DTR and DSR must also be looped. The Flow Control setting for the program must match the Server settings. The CD connection is needed by some terminal programs to simulate Carrier.

Figure 64. DB-9 to DB-25 Crossover (null modem) Cable Connections

Manual Documentation Number: ESP901-902-3704

Appendix A

73

74

Appendix A

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

Image 42
Contents Multi-Interface Ethernet Serial Servers International Headquarters Manual Documentation Number ESP901-902-3704m Table of Contents Using Console Mode Features IntroductionPaired Mode Direct IP ModeVirtual COM Mode Communication ModesSerial Server Configuration Hardware SetupSoftware Installation Serial Server Quick Start GuideInstall Virtual COM Ports on PC Check CommunicationsPackage Checklist ESP901/ESP902 Connections, Indicators and Reset SwitchMaking the Hardware Connections DIP Switches Serial Server/Port Operational ModesSerial Ports RS-232 Mode Console ModeUpgrade Mode RS-422 ModeSerial Server Serial Port Connector Pin-outs DTEAutomatic Installation Installing the Vlinx ESP SoftwareSoftware Installation Manual InstallationUpdating an Existing Installation Opening the ESP ManagerUsing ESP Manager Hardware SetupSoftware Setup Software Overview MenusSerial Server / Virtual COM Lists Search for ServersServer Icons Pane Status BarConfigure Server Properties Search Vlinx ESP Dialogue BoxRestarting Dialogue Box Description of the Server Properties Configuring the Serial Server PropertiesPassword Server NameGateway IP AddressNetmask MAC AddressConnection Mode Serial TimeoutTCP Alive Timeout Flow ControlPort Status Serial Port ModeUpdate/Save TCP/UDP PortFollowing dialogue box will appear Web Server Installing Virtual COM Ports Virtual COM Port InstallationMatching the Serial Server and Virtual COM Port Settings Windows Logo Testing WindowVlinx ESP COM3 Properties Window Removing the Virtual COM Port using Device Manager Removing Virtual COM PortsRemoving the Virtual COM port with ESP Manager Control Panel Window Upgrading Via ESP Manager Upgrading the Serial Server FirmwareDownloading the Firmware Preparing the SoftwareUsing Console Mode Console Mode SetupNavigating the Configuration Menus Using a Password Saving and Restarting the ConfigurationUsing the WEB Server Setting Server PropertiesWeb Server Operation Using Telnet Configuration Using TelnetNavigating the Configuration Menu Telnet Configuration Screens Technical Data ESP901 and ESP902Dhcp Serial Server DB-9 Pin-outs in RS-232 Mode RS-232 Straight-through Cable ConnectionsRS-232 Crossover null modem Cable Connections RS-232 Crossover DB-9 to DB-25 Conversion Connections RS-232 DTE Loopback ConnectionsSerial Server DB-9 Pin-outs in RS-422 Mode Appendix B RS-422 ConnectionsLoopback Connections for RS-422 Serial Server DB-9 Pin-out in RS-485 Mode Appendix C RS-485 ConnectionsStandard Ethernet Cable RJ-45 Pin-out Crossover Ethernet Cable RJ-45 Pin-outElectronics September

ESP902E, ESP902, ESP901E specifications

B&B Electronics offers a series of industrial-grade Ethernet serial servers known as the ESP901E, ESP902, and ESP902E. These devices are specifically designed to connect serial devices to an Ethernet network seamlessly, enabling effective communication and data transfer across various applications.

The ESP901E is engineered for single serial port applications, providing an easy and effective way to connect a serial device to a network. It supports various serial communication protocols, including RS-232, RS-422, and RS-485, making it versatile for a range of devices. One of its standout features is the ability to support 10/100 Mbps Ethernet connectivity, ensuring a reliable and high-speed network connection. Additionally, the ESP901E supports various network protocols, including TCP/IP and UDP, allowing users to integrate the device easily into their existing network infrastructure.

Moving to the ESP902, this model provides dual serial port capabilities, making it ideal for applications requiring the connection of multiple devices. Like the ESP901E, it supports common serial interfaces and offers the same 10/100 Mbps Ethernet connectivity. This flexibility enables it to cater to more complex systems where multiple serial devices need to be integrated into a single network environment. Furthermore, the ESP902 is equipped with features such as automatic baud rate detection, making configuration straightforward and reducing installation time.

The ESP902E enhances the capabilities of the ESP902 with additional features such as enhanced security protocols. It includes support for SSL and SSH, ensuring secure data transmission across the network. This added security layer is crucial for applications that handle sensitive information or require secure communication channels. The ESP902E maintains the user-friendly nature of its predecessors while integrating more advanced features suitable for modern industrial applications.

All three models boast rugged designs suitable for harsh environments, making them perfect for industrial applications without compromising performance. With an extensive operating temperature range and robust housing, these devices can withstand the rigors of factory floors and outdoor installations.

Overall, the ESP901E, ESP902, and ESP902E from B&B Electronics collectively serve to bridge the gap between serial communications and Ethernet networks, supporting various industrial applications while ensuring seamless integration, versatility, and security. Whether for simple single-port connections or more complex multi-port setups, these devices are designed to meet diverse connectivity needs with efficiency and reliability.