GENERAL ADJUSTMENTS
CHAPTER 2 SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
SAFETY INSTRUCTIONS
|
| 36" |
HIGH VOLTAGE AT ZERO BEAM: | (A) | 32.7 kV |
MAX HIGH VOLTAGE: | (B) | 34.1 kV |
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
SPECIFIC INFORMATIONS
Item | Name of adjustment | Preset | Data |
|
|
|
|
RCUT | R CUTOFF | 40H | ← |
GCUT | G CUTOFF | 40H | ← |
BCUT | B CUTOFF | 40H | ← |
GDRV | G DRIVE | 40H | ← |
BDRV | B DRIVE | 40H | ← |
BRTC | BRIGHT CENT | 80H | ← |
TNTC | TINT CENT | 46H | ← |
SCOL | 06H | ← | |
SCNT | 12H | ← | |
HIT | HEIGHT | 40H | ← |
LIN | 14H | ← | |
VSC | 36H | ← | |
VPS2 | 02H | ← | |
VCP | 02H | ← | |
WID | PICTURE WIDTH | 1EH | ← |
|
|
|
|
Item | Name of adjustment | Preset | Data |
|
|
|
|
PARA | 16H | ← | |
CNR | 13H | ← | |
TRAP | TRAPEZIUM | 33H | ← |
HCP | 02H | ← | |
VFC | 0CH | ← | |
HPS | 3FH | ← | |
GMPS | GMPS | 2FH | ← |
CPAR | CENTER PARA | 04H | ← |
PHUE | PIP TINT | 40H | ← |
PCNT | PIP CONTRAST | 0FH | ← |
PCOL | PIP COLOR | 19H | ← |
PYOF | PIP Y OFF SET | 17H | ← |
PIOF | PIP I OFF SET | 24H | ← |
PQOF | PIP Q OFF SET | 1EH | ← |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
OPTION: (PROGRESSIVE 4:3 DV) |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| ||
|
|
|
| MODELS | OPT1 (2CAH) | OPT2(2CBH) | ||||
|
|
|
| HEX |
| HEX | ||||
|
|
|
|
|
|
|
| |||
| 36" |
| 4AH |
| 25H | |||||
|
|
|
|
|
|
|
|
|
| |
| CIRCUIT CHECKS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FAIL SAFE DET. VOLTAGE | (C) | 20.44 V |
| |
|
|
|
|
|
|
|
|
|
|
|
– 14 –