CONVERGENCE ADJUSTMENTS
NOTE: Before attempting any convergence adjustments, the receiver should be operated for at least fifteen minutes.
■CENTER CONVERGENCE ADJUSTMENT
1.Display
2.Adjust the BRIGHTNESS and CONTRAST Controls for well defined pattern.
3.Loosen the tightening ring and adjust two tabs of the
(See figure 3.)
4.Turn the both tabs at the same time keeping the con- stant angle to superimpose red and blue horizontal lines at the centre of the screen. (See figure 3.)
5.Adjust two tabs of
6.Repeat adjustments 3, 4, 5 keeping in mind red, green and blue movement, because
7.After completing the “CENTER CONVERGENCE AD- JUSTMENT” tighten the tightening ring to fix the mag- nets.
MAGNETS
PURITY
MAGNETS
PURITY/CONVERGENCE
MAGNETS
ADJUST THE ANGLE
(VERTICAL LINES)
FIXED
ROTATE TWO TABS AT THE SAME TIME (HORIZONTAL LINES)
ADJUSTMENT OF MAGNETS
SPECIFIC INFORMATIONS GENERAL ADJUSTMENTS
BLU RED
BLU |
RED |
RED/BLUE GRN
RED/BLUE |
GRN |
Figure 4.
■SCREEN-CORNER CONVERGENCE
When the misconvergence is still evident on corners even though the above adjustment is done, use the ferrite sheet
| |
MOVEMENT | MOVEMENT |
Center Convergence by Convergence Magnets
Figure 3.
■Xv COIL ADJUSTMENT
Adjust the Xv coil (on the deflection yoke) to correct misconvergence at both sides on screen.
Use a hexagonal tip stick (plastic) to adjust the core of coil.
(Part No. 23993622) to correct misconvergence.
1.Put ferrite sheets into the space under the yoke. Decide such position that misconvergence becomes minimum, watching picture screen. (See figure below.)
2.Remove cover paper of ferrite sheet to stick it in the place on the tube. Put adhesive tapes on ferrite sheets to fix.
ClockwiseAdjustment Counterclockwiserclockwise Adjustmentent
RB
BR
BR
RB
Ferrite | Ferrite |
Sheets | Sheets |
A
For correcting misconvergence on the position A
XvV Crross Pattern View
– 5 –