Samsung CS29A5HT8X/NWT, CZ21A8VW8X/ELS specifications Safety Precautions, Wire Cord, Plug Reversed

Page 2

Precautions

1. Precautions

Follow these safety, servicing and ESD precautions to prevent damage and protect against potential hazards such as electrical shock and X-rays.

1-1 Safety Precautions

1.Be sure that all of the built-in protective devices are replaced. Restore any missing protective shields.

2.When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including: nonmetallic control knobs and compartment covers.

3.Make sure that there are no cabinet openings through which people—particularly children—might insert fingers and contact dangerous voltages. Such openings include the spacing between the picture tube and the cabinet mask, excessively wide cabinet ventilation slots, and improperly fitted back covers.

If the measured resistance is less than 1.0 megohm or greater than 5.2 megohms, an abnormality exists that must be corrected before the unit is returned to the customer.

4.Leakage Current Hot Check (Figure 1-1): Warning: Do not use an isolation transformer during this test. Use a leakage- current tester or a metering system that complies with American National Standards Institute (ANIS C101.1, Leakage Current for Appliances), and Underwriters Laboratories (UL Publication UL1410, 59.7).

5.With the unit completely reassembled, plug the AC line cord directly into the power outlet. With the unit’s AC switch first in the ON position and then OFF, measure the current between a known earth ground (metal water pipe, conduit, etc.) and all exposed metal parts, including: antennas, handle brackets, metal cabinets, screwheads and control shafts. The current measured should not exceed 0.5 milliamp. Reverse the power- plug prongs in the AC outlet and repeat the test.

 

 

(READING SHOULD

 

LEAKAGE

NOT BE ABOVE

DEVICE

CURRENT

0.5mA)

UNDER

TESTER

 

TEST

 

 

 

TEST ALL

 

 

EXPOSED METAL

 

 

SURFACES

 

 

2-WIRE CORD

 

ALSO TEST WITH

 

 

 

PLUG REVERSED

 

 

 

(USING AC ADAPTER

 

 

EARTH

PLUG AS REQUIRED)

 

GROUND

Fig. 1-1 AC Leakage Test

6.Antenna Cold Check:

With the unit’s AC plug disconnected from the AC source, connect an electrical jumper across the two AC prongs. Connect one lead of the ohmmeter to an AC prong. Connect the other lead to the coaxial connector.

7.X-ray Limits:

The picture tube is especially designed to prohibit X-ray emissions. To ensure continued X-ray protection, replace the picture tube only with one that is the same type as the original. Carefully reinstall the picture tube shields and mounting hardware; these also provide X-ray protection.

8.High Voltage Limits:

High voltage must be measured each time servicing is done on the B+, horizontal deflection or high voltage circuits. Correct operation of the X-ray protection circuits must be reconfirmed whenever they are serviced.

(X-ray protection circuits also may be called “horizontal disable” or “hold-down”.)

Heed the high voltage limits. These include the X–ray Protection Specifications Label, and the Product Safety and X-ray Warning Note on the service data schematic.

Samsung Electronics

www.rtv-horvat-dj.hr

1-1

 

Image 2
Contents Color Television Receiver Chassis KS3AP REV Model CS29A5HT8X/BWTPlug Reversed Safety PrecautionsWire Cord Samsung Electronics Servicing Precautions Precautions for Electrostatically Sensitive Devices ESDs Reference Information Tables of Abbreviations and AcronymsTable of Acronyms IC Line Up Board LOC. no Spec DescriptionFocus Board LOC. no Spec Description Remark MainCRT PIPTCPS3001PD09DS TCPS3001PD09ES Spec Function RemarkTCLS3101PD09AS Function Remark Specifications High voltage Check General Alignment InstructionsAutomatic Degaussing Dynamic Focus Adjustment Screen AdjustmentIbrm E2PROM IC902 Replacement White Balance AdjustmentFactory Adjustment Service ModeMemory Data OSD2B Screen Change I2C BUS Geometric Adjustment PAL ~2552D Video 2 Adjust Soft Limit Slope BWhen PIP is 2-Tuner DolbySlice Level Scart + STuner 5 5 5 IN/OUT Assign DescriptionAssign IN/OUT Active H/L Description IC201S VDP No PowerOFF FBTNo Picture No Sound WINDOW-REMOCON-,725A,-,PC,-,VIOLET INDICATOR-LED-,295A,-,ACRYL,-,CLRBADGE-BRANDAL,SS,SILVER,L65,R2000 KNOB-CONTROL-,725A,-,ABS,HB,GRAYCS29A5HT8X/BWT TU01S C901 C840 AL10uF,20%,25V,WT,TP,5x11,5 DZ602C841 AL1uF,20%,50V,WT,TP,5x11,5 DZ603 DZ605L905 L904INDUCTOR-RADIAL10uH,10%,6x4mm R407 R409DZF01 ICG01ASSY-PCB SUB,AUTO AA95-00840A ,V LDY01 Assy Chassis PARTKS3A,295AHOLDER-,P-CORD,PP,VO,BLK,KE-002 DZY02 ASSY-PCB SUB,AUTO AA95-00681A ,VDZY01 CF+AVBotz CZ21A8VW8X/ELSBOT ASSY-PCB Robot AA94-02037Z ,ERC402 AL470uF,20%,25V,GP,TP,10x16,5 C657 C307 AL100uF,20%,50V,GP,TP,8x11.5,5 C652C308 FILM,MPEF470nF,5%,63V,TP-,5mm C654 C404 AL470uF,20%,25V,GP,TP,10x16,5 C702DIODE-RECTIFIERRU20A,600V,1.5A,-,TP IC HYBRID-,DRGB001A,SIP,5P,-,TPR520 R514R223 R524STOPPER-PCB501H,HIPS,NTR,HB Assy Cabinet FrontCLAMP-FBTABS,V0,BLK BackCLAMP-D,COILNYLON 66,V0,-,-,21A8 AA59-00104A REMOCON-,TM59,DREAM,29,L/GRAY,-,EX,PABlock Diagrams Horvat-dj.hr STD KEY2 KEY1KEY3 GNDRTV servis Horvat Dj.hr Horvat TP26 TP33 TP35 Samsung Electronics 10-5 10-6 CRT, Side AV, Video Switch Double FOCUS, Control Samsung Electronics 10-7