FST Series Product Specifications
3. Reliability Condition
3-1. Temperature Condition
§Temperature Condition Test
Following test are performed in the condition with no dew condensation:
Cold Test: | Tested after leaving the parts in |
| for 2 hours. |
Heat Test: | Tested after leaving the parts in 80°C±3°C for 240 hours and in the room temperature for |
| 2 hours. |
Humidity Test: Tested after leaving the parts in the temperature 60°C±3°C, humidity 90 to 95% for 240
| hours and in the room temperature for 2 hours. | |
Cycle Test: | Tested after 5 cycles of leaving the parts in the temperature | |
| the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C±3°C | |
| for 1 hour and in the room temperature for 0.5 hours. | |
Judgement: | Must satisfy the following: | |
| Activation Force: | Within ±50% of the specification. |
| Linearity: | Must satisfy the specification. |
| Terminal Resistance: | Must satisfy the specification. |
| Insulation Resistance: | Must satisfy the specification. |
| Appearance: | Must satisfy the specification. |
4. Recommended Connector
4-1. Recommended Connector
Part No. | Manufacturer | Pitch | Remarks |
|
|
|
|
J.S.T. Mfg Co., Ltd | 2.54mm | equivalent | |
|
|
|
|
7 | Rev. 2.0 ©2005 - 2006 DMC Co., Ltd. |