AG Neovo FST Series Reliability Condition, Recommended Connector, Temperature Condition

Page 7

FST Series Product Specifications

3. Reliability Condition

3-1. Temperature Condition

§Temperature Condition Test

Following test are performed in the condition with no dew condensation:

Cold Test:

Tested after leaving the parts in -30°C±3°C for 240 hours and in the room temperature

 

for 2 hours.

Heat Test:

Tested after leaving the parts in 80°C±3°C for 240 hours and in the room temperature for

 

2 hours.

Humidity Test: Tested after leaving the parts in the temperature 60°C±3°C, humidity 90 to 95% for 240

 

hours and in the room temperature for 2 hours.

Cycle Test:

Tested after 5 cycles of leaving the parts in the temperature -30°C±3°C for 1 hour and in

 

the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C±3°C

 

for 1 hour and in the room temperature for 0.5 hours.

Judgement:

Must satisfy the following:

 

Activation Force:

Within ±50% of the specification.

 

Linearity:

Must satisfy the specification.

 

Terminal Resistance:

Must satisfy the specification.

 

Insulation Resistance:

Must satisfy the specification.

 

Appearance:

Must satisfy the specification.

4. Recommended Connector

4-1. Recommended Connector

Part No.

Manufacturer

Pitch

Remarks

 

 

 

 

RE-H052SD-1110

J.S.T. Mfg Co., Ltd

2.54mm

equivalent

 

 

 

 

7

Rev. 2.0 ©2005 - 2006 DMC Co., Ltd.

Image 7
Contents Page Table of Contents Product Specifications Size mm Length mm Acceptable Numbers FST Series Product Specifications AppearanceTesting Regulation Testing RegulationFST Series Product Specifications Electrical Characteristics Reliability Condition Recommended ConnectorTemperature Condition Recommended ConnectorConstruction Notes PrecautionsHandling Notes Handling NotesFST Series Product Specifications Mounting Notes Warranty Revision history FST Series Product Specifications