Monarch 120 Introduction, Specifications, Range Resolution Accuracy, Continuity Beeper Range

Page 4

MODEL 120 TRUE RMS MULTIMETER

NOTES

1.0Introduction:

This instrument is a true RMS autoranging digital multimeter capable of measuring AC voltage and current, DC voltage and current, resistance, continuity, frequency, RPM, temperature and capacitance. It is also equipped with a diode testing feature. The instrument complies with IEC 1010-1 1000V CAT III.

2.0Specifications:

AC Voltage (Autoranging):

Range

 

Resolution

 

Accuracy

 

 

Input

Overload Protection

 

 

 

 

 

 

 

 

Impedance

 

 

 

 

 

45Hz~500Hz

 

500Hz~1KHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400mV

 

0.1mV

 

 

 

 

 

 

 

100M ȍ

1200V peak

4V

 

1mV

 

0.5%+5

 

1%+5

 

 

10Mȍ

1200V peak

40V

 

10mV

 

0.5%+5

 

1%+5

 

 

10Mȍ

1200V peak

400V

 

100mV

 

0.5%+5

 

1%+5

 

 

10Mȍ

1200V peak

750V

 

1V

 

0.8%+5

 

1.2%+5

 

 

10Mȍ

1200V peak

AC Current (uA and mA - Autoranging):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

 

Burden

Overload Protection

 

 

 

 

 

 

 

 

Voltage

 

 

 

 

 

45Hz~500Hz

 

500Hz~1KHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400uA

 

0.1uA

 

1.3%+5

 

1.6%+5

 

 

<0.25Vrms

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

4000uA

 

1uA

 

1.3%+5

 

1.6%+5

 

 

<1Vrms

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

40mA

 

10uA

 

1.3%+5

 

1.6%+5

 

 

<0.25Vrms

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

400mA

 

100uA

 

1.3%+5

 

1.6%+5

 

 

<1.5Vrms

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

20A

 

10mA

 

1.5%+5

 

1.8%+5

 

 

<1Vrms

15A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

DC Voltage (Autoranging):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

Input Impedance

Overload Protection

 

 

 

 

 

 

 

 

 

 

 

 

400mV

 

0.1mV

 

0.3%+2

 

 

 

 

100M ȍ

1200Vpeak

4V

 

1mV

 

0.3%+2

 

 

 

 

10Mȍ

1200Vpeak

40V

 

10mV

 

0.3%+2

 

 

 

 

10Mȍ

1200Vpeak

400V

 

100mV

 

0.3%+2

 

 

 

 

10Mȍ

1200Vpeak

1000V

 

1V

 

0.5%+2

 

 

 

 

10Mȍ

1200Vpeak

DC Current (uA and mA - Autoranging):

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

Burden Voltage

Overload Protection

 

 

 

 

 

 

 

 

 

 

 

 

400uA

 

0.1uA

 

0.8%+2

 

 

 

 

<0.25V

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

4000uA

 

1uA

 

0.8%+2

 

 

 

 

<1V

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

40mA

 

10uA

 

0.8%+2

 

 

 

 

<0.25V

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

400mA

 

100uA

 

0.8%+2

 

 

 

 

<1.5V

0.5A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

20A

 

10mA

 

1%+2

 

 

 

 

 

<1V

15A / 600V Fast Blow Fuse

 

 

 

 

 

 

 

 

 

 

 

 

Resistance (Autoranging):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

Resolution

 

Accuracy

 

 

Test Voltage

Overload Protection

 

 

 

 

 

 

 

 

 

 

 

 

400 ȍ

 

0.1 ȍ

 

0.6%+2

 

 

 

 

<1.5VDC

600Vrms

4K ȍ

 

1 ȍ

 

0.6%+2

 

 

 

 

<1.5VDC

600Vrms

40K ȍ

 

10 ȍ

 

0.6%+2

 

 

 

 

<1.5VDC

600Vrms

400K ȍ

 

100 ȍ

 

0.6%+2

 

 

 

 

<1.5VDC

600Vrms

4M ȍ

 

1K ȍ

 

0.6%+2

 

 

 

 

<1.5VDC

600Vrms

40M ȍ

 

10K ȍ

 

1%+3

 

 

 

 

 

<1.5VDC

600Vrms

Continuity Beeper:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Range

 

 

 

Active Range

 

 

 

Test Voltage

Overload protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Under 40 ȍ

 

 

 

 

<1.5V

600Vrms

1

Image 4
Contents Monarch True RMS MultimeterSafeguards and Precautions Limited WarrantyTable of Contents Declaration of ConformitySpecifications Range Resolution AccuracyDC Current uA and mA Autoranging Range Resolution Accuracy IntroductionBattery and Fuse Replacement Symbol Definitions and Button Locations Temperature MeasurementsOperating conditions Frequency and RPM MeasurementsFunction Selector Rotary Switch Range Button Resistance MeasurementsDiode Tests MAX/MIN ButtonOperating Instructions