Regency 9.957.03605 Receiver, Installation, Wall Mounting, Hearth Mounting

Page 5
Fig. 4

RECEIVER

The Proflame Receiver (Fig. 3) connects directly to the gas valve and stepper motor with a wiring harness. The Receiver is powered by 4 AA type batteries. The Receiver accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with with the particular Proflame system configuration. The Receiver three position slider switch can be set to one of three positions: ON (Manual Override), Remote (Remote control) or Off.

PRG Key

12 PIN terminal

3 Positions Slider

Fig. 3: Proflame Receiver body.

INSTALLATION

The Receiver can be placed inside a standard Junction type wall box or a low temperature area of the appliance.

Wall Mounting

1.Connect the wiring harness to the back of the Receiver.

2.Install the Receiver in the Junction box using the existing J box screws. (Fig. 4)

3.Insert the 4 AA type batteries in the battery compartment with the correct polarity.

4.Place the slider into the cover plate.

5. Put the Receiver switch in the “OFF” position.

6. Make sure the Receiver and cover plate words “ON” and “UP” are on the same side.

7.Align the slider with the switch on the Receiver and couple the switch into the slider.

8.Align the screw holes.

9.Using the two (2) screws provided secure the cover plate to the Receiver.

Hearth Mounting

1.Connect the wiring harness to the back of the Receiver.

2.Install the 4 AA type batteries in the battery compartment with the correct polarity. 3.Make sure the Receiver and cover plate words “ON” and “UP” are on the same side.

4.Place the slider into the cover plate.

5.Align the slider with the switch on the Receiver and couple the switch into the slider.

6.Using the two (2) screws provided secure the cover plate to the Receiver.

ENGLISH

5

Image 5
Contents Proflame GTM System English Remote Control Technical DataSystem Description Transmitter Remote Control with LCD DisplayReceiver InstallationWall Mounting Hearth MountingInitializing the System for the first time Operating ProcedureConnecting to the Gas Valve Turn off the Aplliance Temperature indication DisplayTurn on the Appliance Room Thermostat Transmitter Operation Remote Flame ControlSmart flame function Smart Thermostat Transmitter OperationReceiver TransmitterFire Hazard. Can cause severe injury or death Dimensional Drawings