Connecting to the Gas Valve

The wiring harness for the Proflame GTM system has two wires labeled “TH” & “TPTH”. Connect the wires to the gas valve as labeled. (TH to TH and TPTH to TPTH). Additionally there is a connector labeled “Motor”. Connect this “Motor” connector to the stepper motor on the gas valve. (Fig. 5)

REMOTE

 

 

REMOTE

 

 

TH

 

 

TP

(+) (-)

 

 

 

Red

 

 

Black

 

 

 

White

Green

TPTH

 

 

Fig. 5: Wiring diagram.

OPERATING PROCEDURE

Initializing the System for the first time

Install the 4 AA batteries into the receiver battery bay. Note the polarity of battery and insert into the battery bay as indicated on the Battery cover (+/-). Place the 3 position slider switch in the “Remote” position.

Using the end of a paper clip, or other similar object, insert the end of the paper clip into the hole marked “PRG” on the Receiver front cover. The Receiver will “beep” three (3) times to indicate that it is ready to synchronize with a Transmitter. Install the 3 AAA type batteries in the Transmitter battery bay, located on the base of the Transmitter. With the batteries already installed in the Transmitter, push the On button. The Receiver will “beep” four times to indicate

6 the Transmitter’s command is accepted and sets to the particular code of that Transmitter. The system is now initialized.

Image 6
Contents Proflame GTM System English Technical Data Remote ControlTransmitter Remote Control with LCD Display System DescriptionWall Mounting InstallationReceiver Hearth MountingOperating Procedure Connecting to the Gas ValveInitializing the System for the first time Temperature indication Display Turn on the ApplianceTurn off the Aplliance Remote Flame Control Room Thermostat Transmitter OperationSmart Thermostat Transmitter Operation Smart flame functionTransmitter ReceiverFire Hazard. Can cause severe injury or death Dimensional Drawings