Specifications — SPK Series Cable
Description | UL NEC/ | No. | Standard | Shipping | Conductor | Nominal | Nominal | ||
| C(UL) CEC | Lengths | Weights | (stranding) | Core OD | OD | |||
Part No. (length) | of | ||||||||
UL AWM |
|
|
| Diameter |
|
| |||
Cond. | Ft. | m | Lbs. kg | Inch mm | Inch mm | ||||
Model | Temp. |
| Nom. DCR | ||||||
|
|
|
|
|
|
|
|
|
(1 pair) 18, 16, or 14 AWG Twisted Pairs |
|
|
|
|
|
|
|
|
|
| |
Nonplenum Cable • PVC Inner Jackets • PVC Outer Jacket |
|
|
|
|
|
|
|
|
|
| |
NEC | 1 | 1000 | 304.8 | 30 | 13.6 | 18 AWG | 0.068 | 1.73 | Single: | ||
SPK18 | CM | twisted |
|
|
|
| (16/30) |
|
| red, black | |
C(UL) | pair |
|
|
|
| 0.048", 1.21 mm, |
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
| 60 °C |
|
|
|
|
| Cu |
|
| Overall: | |
|
|
|
|
|
| 6.2 ohms/1k ft, |
|
| |||
Minimum bend radius: 1.5” |
|
|
|
|
|
|
|
| 0.165 | 4.19 | |
|
|
|
|
|
| 20 ohms/1 km |
|
| white |
| |
NEC | 1 | 1000 | 304.8 | 38 | 17.2 | 16 AWG | 0.073 | 1.86 | Single: | ||
SPK16 | CM | twisted |
|
|
|
| (65/34) |
|
| red, black | |
C(UL) | pair |
|
|
|
| 0.053", 1.35 mm, |
|
|
|
| |
|
|
|
|
| Cu |
|
|
|
| ||
| 60 °C |
|
|
|
|
|
|
| Overall: | ||
|
|
|
|
|
| 4.2 ohms/1k ft, |
|
| 0.199 | 5.05 | |
|
|
|
|
|
|
|
|
| |||
Minimum bend radius: 2.0” |
|
|
|
|
|
| 13.8 ohms/1 km |
|
| white |
|
NEC | 1 | 1000 | 304.8 | 51 | 23.1 | 14 AWG | 0.080 | 2.04 | Single: | ||
SPK14 | CM | twisted |
|
|
|
| (41/30) |
|
| red, black | |
C(UL) | pair |
|
|
|
| 0.067", 1.70 mm, |
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
| 60 °C |
|
|
|
|
| Cu |
|
| Overall: | |
|
|
|
|
|
| 2.7 ohms/1k ft, |
|
| 0.244 | 6.20 | |
|
|
|
|
|
|
|
|
| |||
Minimum bend radius: 2.5” |
|
|
|
|
|
| 8.9 ohms/1 km |
|
| white |
|
Plenum Cable • PVC | Insulation • Blue |
|
|
|
|
|
|
|
|
|
|
NEC | 1 | 1000 | 304.8 | 18 | 8.2 | 18 AWG | 0.062 | 1.58 | Single: | ||
SPK18P | CMP | twisted |
|
|
|
| (16/30) |
|
| red, black | |
C(UL) | pair |
|
|
|
| 0.048", 1.21 mm, |
|
|
|
| |
|
|
|
|
|
|
|
|
| |||
| NFPA 262 |
|
|
|
|
| Cu |
|
| Overall: | |
| 60 °C |
|
|
|
|
| 6.2 ohms/1k ft, |
|
| 0.141 | 3.58 |
Minimum bend radius: 4.0” |
|
|
|
|
| 20 ohms/1 km |
|
| blue |
| |
|
|
|
|
|
|
|
|
| |||
NEC | 1 | 1000 | 304.8 | 29 | 13.2 | 16 AWG | 0.067 | 1.71 | Single: | ||
SPK16P | CMP | twisted |
|
|
|
| (65/34) |
|
| red, black | |
C(UL) | pair |
|
|
|
| 0.053", 1.35 mm, |
|
|
|
| |
|
|
|
|
| Cu |
|
| Overall: | |||
| NFPA 262 |
|
|
|
|
|
|
| |||
| 60 °C |
|
|
|
|
| 4.2 ohms/1k ft, |
|
| 0.159 | 4.04 |
Minimum bend radius: 4.0” |
|
|
|
|
| 13.8 ohms/1 km |
|
| blue |
| |
|
|
|
|
|
|
|
|
| |||
NEC | 1 | 1000 | 304.8 | 41 | 18.6 | 14 AWG | 0.087 | 2.22 | Single: | ||
SPK14P | CMP | twisted |
|
|
|
| (41/30) |
|
| red, black | |
C(UL) | pair |
|
|
|
| 0.067", 1.70 mm, |
|
|
|
| |
|
|
|
|
|
|
| Overall: | ||||
| NFPA 262 |
|
|
|
|
| Cu |
|
| ||
| 60 °C |
|
|
|
|
| 2.7 ohms/1k ft, |
|
| 0.196 | 4.98 |
Minimum bend radius: 4.5” |
|
|
|
|
| 8.9 ohms/1 km |
|
| blue |
| |
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| 02 December, 2008 |