Extron electronic SPK Series specifications Nonplenum Cable PVC Inner Jackets PVC Outer Jacket

Page 1

Specifications — SPK Series Cable

Description

UL NEC/

No.

Standard

Shipping

Conductor

Nominal

Nominal

 

C(UL) CEC

Lengths

Weights

(stranding)

Core OD

OD

Part No. (length)

of

UL AWM

 

 

 

Diameter

 

 

Cond.

Ft.

m

Lbs. kg

Inch mm

Inch mm

Model

Temp.

 

Nom. DCR

 

 

 

 

 

 

 

 

 

(1 pair) 18, 16, or 14 AWG Twisted Pairs

 

 

 

 

 

 

 

 

 

 

Nonplenum Cable • PVC Inner Jackets • PVC Outer Jacket

 

 

 

 

 

 

 

 

 

 

22-150-03 (1000')

NEC

1

1000

304.8

30

13.6

18 AWG

0.068

1.73

Single:

SPK18

CM

twisted

 

 

 

 

(16/30)

 

 

red, black

C(UL)

pair

 

 

 

 

0.048", 1.21 mm,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 °C

 

 

 

 

 

Cu

 

 

Overall:

 

 

 

 

 

 

6.2 ohms/1k ft,

 

 

Minimum bend radius: 1.5”

 

 

 

 

 

 

 

 

0.165

4.19

 

 

 

 

 

 

20 ohms/1 km

 

 

white

 

22-151-03 (1000')

NEC

1

1000

304.8

38

17.2

16 AWG

0.073

1.86

Single:

SPK16

CM

twisted

 

 

 

 

(65/34)

 

 

red, black

C(UL)

pair

 

 

 

 

0.053", 1.35 mm,

 

 

 

 

 

 

 

 

 

Cu

 

 

 

 

 

60 °C

 

 

 

 

 

 

 

Overall:

 

 

 

 

 

 

4.2 ohms/1k ft,

 

 

0.199

5.05

 

 

 

 

 

 

 

 

 

Minimum bend radius: 2.0”

 

 

 

 

 

 

13.8 ohms/1 km

 

 

white

 

22-152-03 (1000')

NEC

1

1000

304.8

51

23.1

14 AWG

0.080

2.04

Single:

SPK14

CM

twisted

 

 

 

 

(41/30)

 

 

red, black

C(UL)

pair

 

 

 

 

0.067", 1.70 mm,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60 °C

 

 

 

 

 

Cu

 

 

Overall:

 

 

 

 

 

 

2.7 ohms/1k ft,

 

 

0.244

6.20

 

 

 

 

 

 

 

 

 

Minimum bend radius: 2.5”

 

 

 

 

 

 

8.9 ohms/1 km

 

 

white

 

Plenum Cable • PVC

Insulation • Blue Fire-resistant PVC Outer Jacket

 

 

 

 

 

 

 

 

 

 

22-153-03 (1000')

NEC

1

1000

304.8

18

8.2

18 AWG

0.062

1.58

Single:

SPK18P

CMP

twisted

 

 

 

 

(16/30)

 

 

red, black

C(UL)

pair

 

 

 

 

0.048", 1.21 mm,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NFPA 262

 

 

 

 

 

Cu

 

 

Overall:

 

60 °C

 

 

 

 

 

6.2 ohms/1k ft,

 

 

0.141

3.58

Minimum bend radius: 4.0”

 

 

 

 

 

20 ohms/1 km

 

 

blue

 

 

 

 

 

 

 

 

 

 

22-154-03 (1000')

NEC

1

1000

304.8

29

13.2

16 AWG

0.067

1.71

Single:

SPK16P

CMP

twisted

 

 

 

 

(65/34)

 

 

red, black

C(UL)

pair

 

 

 

 

0.053", 1.35 mm,

 

 

 

 

 

 

 

 

 

Cu

 

 

Overall:

 

NFPA 262

 

 

 

 

 

 

 

 

60 °C

 

 

 

 

 

4.2 ohms/1k ft,

 

 

0.159

4.04

Minimum bend radius: 4.0”

 

 

 

 

 

13.8 ohms/1 km

 

 

blue

 

 

 

 

 

 

 

 

 

 

22-155-03 (1000')

NEC

1

1000

304.8

41

18.6

14 AWG

0.087

2.22

Single:

SPK14P

CMP

twisted

 

 

 

 

(41/30)

 

 

red, black

C(UL)

pair

 

 

 

 

0.067", 1.70 mm,

 

 

 

 

 

 

 

 

 

 

 

Overall:

 

NFPA 262

 

 

 

 

 

Cu

 

 

 

60 °C

 

 

 

 

 

2.7 ohms/1k ft,

 

 

0.196

4.98

Minimum bend radius: 4.5”

 

 

 

 

 

8.9 ohms/1 km

 

 

blue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02 December, 2008

Image 1
Contents Insulation Blue Fire-resistant PVC Outer Jacket Nonplenum Cable PVC Inner Jackets PVC Outer Jacket