ADTRAN system manual Adtran Tracer 3202 Cable Kit Instructions, Background, Directions

Page 1

ADTRAN Tracer 3202 Cable Kit Instructions

Background

Newer models of the Tracer 3202 outdoor unit will have 1.5 to 2 meters of twisted pair cable (“pigtail”) preattached to the 3202 base. The twisted pair conductors are pre-stripped and ready for crimping and attachment to a receptacle connector. A receptacle connector kit is available that will mate to existing customer-end cable connectors used with the original 3202 model. The contents of this kit include:

1 CPC (circular plastic connector) receptacle

1 CPC strain relief

4 receptacle crimping pins (male gender)

The instructions described in this document refer to the 3202 pre-attached cable only. For instructions on attaching the plug connector to the customer cable, please consult the Tracer 2210/3202 System Manual (provided on the Tracer 2210/3202 Documentation CD).

Directions

Figure 1 shows a detailed view of the connector assembly required to attach the receptacle connector to the pre-attached 3202 cable. The plug connector assembly is shown for reference only.

Receptacle Connector with Strain Relief

Plug Connector

(3202 end)

(Customer end)

x 2

P1

A B

A B

P2

3202 Pigtail Cable

Detail A – A

1

2 3

4

Schematic

11

22

33

44

P1 P2

Customer Cable

Detail B – B

1

2 3

4

Figure 1 – Connector Assembly Diagram

The provided 3202 pigtail cable has heat shrink tubing on conductor pairs 1 and 2. Insert the 1,2 pair in the 1,2 slots in the receptacle, without regard to which conductor is wired to conductor 1 or conductor 2. Likewise, insert the 3,4 pair in the 3,4 slots in the receptacle, without regard to which conductor is wired to conductor 3 or conductor 4.

61280012L1-10A

© ADTRAN, 2002

1

Image 1
Contents Background Adtran Tracer 3202 Cable Kit InstructionsDirections Crimp Terminal Details side view