ADTRAN Tracer 3202 system manual Crimp Terminal Details side view

Page 2

Care should be taken when crimping the crimp terminals onto the bare conductors. The centermost flanges should make contact with the bare conductor, while the outermost flanges should crimp onto the insulator. See Figure 2 below for details.

Bare Conductor (x4)

Insulator (x4)

 

Outer Flange

 

Center Flange

Crimp Terminal (x4)

Figure 2 – Crimp Terminal Details (side view)

The strain relief hardware should be installed after crimping each pin to a crimp terminal and inserting each into the appropriate receptacle position. Twist the strain relief shell onto the receptacle prior to tightening the strain relief screws. The strain relief should apply pressure to the outer twisted pair sheath, which bundles the individual conductor insulators, and not to the individual insulators themselves.

61280012L1-10A

© ADTRAN, 2002

2

Image 2
Contents Directions Adtran Tracer 3202 Cable Kit InstructionsBackground Crimp Terminal Details side view