EverFocus EDSR-900 instruction manual 11.1 RS-485 Remote Control, RJ45 RS485 pin assignment

Page 41

11. REMOTE CONTROL

11.1 RS-485 REMOTE CONTROL

The new standard EverFocus EDSR remote protocol allows challenging installations with DVR remote control at different installation sites.

EDSR remote control is supported by the keyboards KS-KBJ(with 3-axis joystick and 2 additional RS-485 – Ports for telemetry control with independent telemetry protocols) and KS-KBK(no telemetry).

Up to 32 units are allowed in the RS-485 bus. The RS-485 bus requires serial wiring with 2-wire shielded twisted pair cable(“daisy chain”). Maximum cable lenght of the bus is 1200 m.

Star wiring is only possible with additional RS-485 distributor. Mixed installation is possible with following recorder types:

EDSR100H, EDSR100M, EDSR400, EDSR400H, EDSR400M, EDSR900, EDSR1600 For installation details please consult the manuals of KS-KBK and KS-KBJ keyboard.

Installation example (2 remote operators, 1 EDSR900, 1 EDSR1600) :

 

MAIN1

M1-1

M1-2

M1-3 M1-4

DVR1: EDSR1600

 

Video 1 x

 

 

 

 

 

 

 

 

 

 

Video 5 x

 

 

 

 

 

RS-485 2 wire

 

 

 

 

 

DVR2: EDSR900

 

 

 

 

 

Video 5 x

 

 

 

 

 

Video 1 x

CALL 1 CALL 2

MAIN2

M2-1

M2-2

M2-3 M2-4

 

 

RS-485 2 wire

 

 

 

RS-485 2 wire

Operator 1:

1x Full screen view DVR1

1x Full screen view DVR2

Operator 2:

1x Multi screen view DVR1 (MAIN)

4x Full screen view DVR1 (MATRIX)

1x Multi screen view DVR1 (MAIN)

4x Full screen view DVR2 (MATRIX)

RJ45 (RS485) pin assignment

There are two RJ-45 (RS-485) connectors on the back panel of the DVR (loop through). Please refer the following pin assignment for application.

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN

FUNCTION

 

1

2

3

4

5

6

 

7

8

 

 

 

 

 

 

 

 

1

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

RX +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

RX -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

36

Image 41
Contents V1.02 EDSR-1600Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Main FeaturesProduct Overview Specifications Back Panel Connections Back Panel ConnectionsON/OFF AC100~240VAlarm I/O Refer pin assignment in Appendix-C, System Connection Before InstallationSystem Connection Front Panel Keypads Front Panel KeypadsShuttle Ring and JOG Dial Chanel KeysIR Remote Controller receiver Operation OperationMenu Flow Menu flowBuzzer ControlArchive MatrixCLOCK/LANGUAGE Setting Menu , we define Clock Setting MenuOFF Timer Setting MenuTimer Setting Menu Week Start Stop Speed SET SUN Sequence Setting Menu CH OP Dwell Sequence Setting MenuSequence Setting MENU, we define for Main Monitor Title Setting Menu CH Title Title Setting MenuTitle Setting Menu , we define Covert Setting Menu , we define Covert Setting MenuDefault setting is OFF for all cameras Covert Setting Menu CH OP OFFAlarm Recording MENU, we define Alarm Record Setting MenuOP Operation Default OFF Motion Setting MenuMotion Record Setting MENU, we define HIT 1-9/16 to Manual Edit Record Setting Menu Network Setting MENU, we define Network Setting MenuUSER-NAME Password Level MAC AddressControl Setting MENU, we define Control Setting MenuBuzzer Setting Menu Picture Size Archive Setting MenuTime Stamp Water MarkDialog Matrix Setting MenuCH, DWELL, Event Call MonitorSystem Setting MENU, we define System Setting MenuPlay with Audio AUDIO-1, AUDIO-2 Disk Usage HDD-1, HDD-2Recording Alarm RecordingInstant Recording RECNormal Playback Playing BackPlay PauseSearch Playback Search PlaybackSearch EnterHDD2 Alarm List search playbackSearch Stop Date/Time Search PlaybackPause Copy Data ExportStill Image Copy Menu Copy to Movie FileExport Event LOG List AlarmDisplay CallMonitor Views / Operation Mode Display ZoomCall / Matrix monitors Main MonitorSequence Call / Matrix MonitorsRJ45 RS485 pin assignment Remote Control11.1 RS-485 Remote Control With EDSR-1600 recorder IR Remote ControllerIR Remote Controller optional View From Internet/Intranet Step Backward the Video Playback display Control Mode To switch to direct remote control modePause To pause the Video Playback display View From Internet/Intranet View From Internet/Intranet Appendix-A SpecificationsAppendix-B ? When Recording with 160GB HDDPicture Quality KB Lower LOW Basic Standard High Superior? When Recording with 320GB HDD Pin assignment of the D-SUB 9-pin connector Appendic C Serial Interface SpecificationsTransmission setting RS-232 pin assignmentSample control code packets Remote Control ProtocolLength Byte Format of message packet is as followsReceiver ID Remote keys OPcode=0x4B Opcode Byte & Data bytesOPcode Checksum Byte Matrix command OPcode=0x4DAppendix-D Alarm I/O pin assignmentDVR PIN #Beijing Office Head Office European OfficeUSA Office Japan Office