1 SDDS Print Master Format
1.3Synchronisation
Sampling frequency 44.1kHz. i.e. 44100 samples for every 24 frames of picture. 48kHz can be used, but this will be
T imecode 25 frames per second, referenced to 50Hz, film speed 24 fps
Or 30 frames per second, non drop frame, referenced to 60Hz, film speed 24fps NOT E: For NT SC referenced mixing, the master tape must be
T imecode must be referenced to the digital audio. Reel 1 = 1 hour start, reel 2 = 2 hour etc.
Head pop/sync pip should start two seconds or 3 feet before the first frame of picture. e.g. for reel 1, pip at 1:00:06:00, first frame at 1:00:08:00.
1.4Audio and levels
Operating level is
Channel | SPL |
LEFT | 85 |
LEFT CENT RE | 85 |
CENT RE | 85 |
RI GHT CENT RE | 85 |
RI GHT | 85 |
SUBWOOFER | Approx 91 see* |
LEFT SURROUND | 82 |
RI GHT SURROUND | 82 |
*T he subwoofer channel has 10dB of in band gain. For a full explanation of this, see the “Subwoofers” section on page 21.
T ones should be recorded on all used channels at the head of each reel. 30 seconds each of 1kHz at
Surround delay is set in the cinema processor. No delay on the master.
Overlap. 2 seconds or 3 feet of audio from the subsequent reel must be recorded after the end of the reel. T his can optionally end with a tail pip.
A/D conversion. No audio
SDDS Print Master Guidelines, Page 5 of 26