Philips BDL4631V user manual Remote control numbering function, SUB Hdmi PC-A CVI Videos Main

Page 44

User Manual BDL4631V/00

NOTE 3: “PIP”, “POP” and “SIDE BY SIDE”

The following table shows the combination of signal inputs under which the “PIP” and “POP” modes function. These modes do not function, however, when the screen size is “CUSTOM” or “REAL”.

SUB

HDMI 1

HDMI 2

PC-A

CVI

VIDEO<S>

VIDEO

 

HDMI 1

 

 

 

 

 

 

 

 

HDMI 2

 

 

 

 

 

 

 

MAIN

PC-A

CVI

 

VIDEO<S>

 

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

 

 

: Supported

: Not supported

Press the “PIP ON/OFF” buttons on the remote control to change between “PIP”, “POP” and “SIDE BY SIDE” mode as shown in the diagram below.

PIP

 

 

POP

 

 

SIDE BY SIDE

 

 

SIDE BY SIDE

 

 

 

 

 

ASPECT

 

 

 

FULL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A B

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

 

 

A

B

 

 

 

 

 

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

“PIP”, “POP” mode resolution (Reference)

 

 

PIP SIZE

SMALL

: 320 dots X 240 dots

 

MIDDLE

: 480 dots X 320 dots

 

LARGE

: 640 dots X 480 dots

POP SIZE

 

: 320 dots X 240 dots

OFF

A

< Remote control numbering function >

By connecting multiple BDL4631V monitors using RS-232C cables, you can control any one monitor or all the monitors by one remote controller.

1.Assign arbitrary ID number to each of multi-connected BDL4631V monitors using MONITOR ID. ID numbers 1 to 26 are selectable.

It is recommended to assign sequential ID numbers from 1 and up.

2.The remote control mode of the first BDL4631V monitor is set to PRIMARY and those of the other monitors are set to

SECONDARY.

3.When you direct the remote controller at the remote control signal sensor of the PRIMARY monitor and press the DISPLAY button on the remote controller, the ID selection OSD appears at the upper left of the screen.

ID number of the currently viewed monitor

Select the ID number of the monitor you want to control using the +/- button on the remote controller.

The ID of the monitor you want to control is displayed at the upper left of its screen. By selecting ALL, you can control all the multi-connected monitors.

4.Direct the remote controller at the remote control signal sensor of the PRIMARY monitor. OSD appears on the monitor having the ID number you selected.

NOTE:

When the ID selection OSD is being displayed on the PRIMARY monitor, press the DISPLAY button on the remote controller again to cancel the ID selection OSD and then control the monitor you selected.

HINT:

If you set the remote control mode wrongly and remote control operation becomes unavailable, press any button on the control panel of the monitor to display the OSD screen and change the remote control mode using ADVANCED OPTION. By pressing

and holding down the DISPLAY button on the remote control for 5 seconds or longer, the remote control mode is initialized to

NORMAL.

41

Image 44
Contents Philips Professional Business Solutions Table of Contents Page Safety Instructions Regulatory Information CE Declaration of Conformity Polish Center for Testing and Certification Notice Information for UK only 环保使用期限 North Europe Nordic Countries Information Contents Elements Name and Functions Control PanelTerminal Panel Audio OUTRemote Control Power buttonOperating Range for the Remote Control Handling the remote controlHow to Mount or Attach Feet to the LCD Monitor Way 1 Attach and remove the optional feetWay II Mount the monitor on the wall To avoid monitor from fallingVentilation Requirements for enclosure locating Setup Procedure To prevent the main power switch from being changed Adjust the imageRecommended Adjustment Install the LCD Monitor in Portrait Mode How to set-upBefore making connections Connectivity DiagramConnectivity Connecting to a Personal Computer Connecting the LCD Monitor to a Personal ComputerConnecting to a Digital Interface Equipment Connect the LCD Monitor to a Computer with a Digital OutputConnecting to a DVD Player Connect the LCD Monitor to a DVD PlayerConnecting to a Stereo Amplifier Connect the LCD Monitor to a Stereo AmplifierPower on and OFF Modes Pressing the Main Power SwitchPressing the power button Using the remote controlPower Indicator Using Power ManagementDisplay Signal of Video Source Setting to Video Picture SizeSmart Picture Mode Audio Source SwitchingControl Lock Mode OSD InformationOSD On-Screen-Display Controls Brightness ContrastSharpness Black LevelColor Control Color TemperaturePicture Reset Zoom Mode PositionScreen Reset Custom ZoomAudio Reset BalanceTreble BassPIP Audio PIP ResetPIP Size Panel Saving Power SaveLanguage Configuration Reset Factory ResetSleep Timer OSD Turn OFFInformation OSD OSD H PositionMonitor Information Advanced Option Gamma SelectionIR Control Keyboard ControlTiling Date and TimeAdvanced Option Reset ScheduleMonitor ID DDC/CIRecommendations For long life use of Public DisplayImage Sticking of LCD Panel Remote control numbering function SUB Hdmi PC-A CVI Videos MainFeatures SRGB Color ControlTroubleshooting Remote Control is not available SCHEDULE/SLEEP Timer function is not working properlyNo Signal is displayed on the screen No SoundSpecifications Specifications BDL4631VPin Assignment SDA