Black Box AC1120A, 1123A, 1121A, 1122A Primary RS-232 Control Port, Auxiliary RS-232 Control Port

Page 10

Model AC1120A, AC1121A, AC1122A, AC1123A

The main RS-232 port is on a screw terminal and the auxiliary port is on an RJ45.

Caution on RJ45 Control Input

Since the matrices with the IP control and those without both have an RJ45 connector next to the RS-232 screw terminal, it is easy to confuse their function. The function of the connector should be labeled above it. A sure way to tell if the RJ45 control input is LAN or Serial is by the existence of little LED indicators to the sides of the connector. If the connector has these lights, then it is a LAN connection, otherwise it is an RS-232 serial connection.

Figure 6 – IP input versus Auxiliary RS-232

2.4.1.1 Primary RS-232 Control Port

This is a 3-terminal captive screw input. A detachable mating connector is provided. The function of each pin is designated on the panel above the connector. Below is a diagram for connection this port to a PC’s DB9 serial port.

Figure 7 – Primary RS-232 to PC cable

2.4.1.2 Auxiliary RS-232 Control Port

The matrix switches without IP control have a secondary serial port that can work independently of the primary port. The user can control the matrix from either or both ports.

The auxiliary RS-232 is on an RJ45. Make sure to not connect this to any LAN devices. The pinout for the auxiliary RS-232 follows the basic EIA-561 for TX RX and Ground. Optional current limited 12v DC may also be provided (max rated output current of 50ma) that can be used to power external keypads or control devices.

Caution High-Voltage

Never open the unit’s cover. Lethal voltages exists inside the unit

Opening the unit also voids the warranty on the unit.

The pinout is shown below.

8

Image 10
Contents Models AC1120A 1121A 1122A 1123A Page Trademarks Used in this Manual Table of Contents Maintenance and Troubleshooting Features General Installation Input Audio & Video ConnectionsTechnical Note about the Audio Inputs Output Audio & Video ConnectionsControl Inputs Power input connectionMatrix with RS-232 Control no IP Primary RS-232 Control Port Auxiliary RS-232 Control PortOperation Front-Panel Buttons and IndicatorsUnits with IP control Viewing Audio and Video Routings or Ties Viewing ties by Video and AudioViewing ties by Video only Viewing ties by Audio only Making Audio and Video Routings or TiesMaking a tie by Input Video and Audio to follow each other Video only or Audio only Making a tie by Output Video and Audio to follow each otherDisconnecting all AV outputs blank preset Recalling Presets routing patternsSaving Presets routing patterns To reset system to factory defaultsComparison with Analog VU meter on 16x16 Matrix Control Commands RS-232 and IP Front panel is in usecrTo make a video tie Naming FunctionsRouting Functions To make an audio tieRebooting the System Preset Pattern Saving and Routing FunctionsRestoring Factory Defaults To recall a saved preset Video routing patternTo Read the Firmware Version To Read Audio Volume Units VU of output #1To Read Temperature inside the Matrix To Read Supply VoltagesScheduling Auto recall of Preset Patterns To set a scheduleResponse if 4 was entered schedule on IP Control Basics If command completed successfully Response BB1123-A IP Configuration through port Model AC1120A, AC1121A, AC1122A, AC1123A Page Troubleshooting Maintenance and TroubleshootingMaintenance Calling Black BoxSpecifications Shipping and PackagingFunction Procedure Appendix 1 Front Panel Quick Reference GuideAppendix 2 Command Summary Command FunctionModel AC1120A, AC1121A, AC1122A, AC1123A Page Copyright 2008. Black Box Corporation. All rights reserved