INSTALLATION INSTRUCTIONS

INSTALLATION

1.CONTROL UPGRADE

1.1Your stove is fitted with a control valve that can be upgraded to battery powered Remote Control. This upgrade can be fitted by anyone capable of simple DIY jobs. Your Yeoman dealer keeps two versions of the remote:

1.2STANDARD REMOTE CONTROL (Yeoman PART NUMBER YM-8455)

This remote controls the gas stove after the pilot has been lit to:

Turn on the main burner

Regulate the flame from low to high and back

Turn off the burner leaving just the pilot burning

1.3THERMOSTATIC AND TIMER REMOTE CONTROL (Yeoman PART NUMBER YM-8456)

This remote controls the gas stove after the pilot has been lit. In ‘MANUAL MODE’ you can:

Turn on the main burner

Regulate the flame from low to high and back

Turn off the burner leaving just the pilot burning

In ‘AUTO MODE’ you can:

Set the room temperature so the stove automatically maintains that temperature

In ‘TIMER MODE’ the stove:

Turns on and off according to the set time periods

Automatically regulates the room temperature during the set periods

2.SAFETY PRECAUTIONS

2.1For your own and other’s safety, you must install this stove according to local and national codes of practice. Failure to install the stove correctly could lead to prosecution:

Read these instructions before installing and using this stove.

2.2All the instructions must be left intact with the user.

2.3Make sure you install the stove in a sufficiently ventilated space.

2.4This stove is intended for use on a governed gas installation and set to the required pressure.

2.5Keep all plastic bags away from young children.

2.6Do not place any object on or near the stove and allow adequate clearance above the stove. See Diagram 2 and 2A, Site Requirements.

2.7The stove is fitted with the Gazco Flue Sure System which cuts off the gas supply to the burner if the flue does not operate correctly. This means there may be insufficient flue pull. If this happens, wait 10 before trying to relight.

Repeated shutdown may indicate a serious problem. You must investigate both the flue and the Flue Sure device - refer to Servicing Instructions, Replacing Parts, Section 3.

3. INSTALLATION OF THE STOVE

Flue Pipe Installation

The stove is factory built for rear and top flue exit

3.1• Unpack the accessories carton and stove unit

Position the stove observing all clearance measurements

Adjust the balance of the stove using the bolts in the legs to make it level

3.2Rear Exit Flue

WALL THICKNESS MIN 200 mm MAX 600 mm

Unpack the adjustable flue and terminal guard

Take care not to lose fixings

Decide on final stove position

Ensure you comply with clearance for external flue terminal, see Site Requirements, 1.

Mark the centreline of the stove on the wall

Mark the height from the hearth to the flue centre, Diagram 1

1

AR0605

TAKE CARE WHEN MARKING OUT FOR THIS FLUE; IT IS DIFFICULT TO MOVE FOLLOWING INSTALLATION

Create a 152mm (6”) diameter hole for the flue by a) Core Drill

b) Hammer and chisel

(We advise drilling small holes around the circumference for method b). Make good at both sides of the hole.

3.3Setting the flue length

Measure the total wall thickness and add 65mm - this gives a minimum clearance between the back of the stove and the wall.

Insert the square cardboard fitment into the flue to support the inner flue

Cut through the flue and fitment, Diagram 2

Image 12
Contents Dartmoor Contents Appliance Commissioning Checklist Flue Check PassGAS Check User Instructions GeneralLighting the Stove Turning the Stove OFFCleaning the Fire Standard Remote Control Yeoman Part Number YM-8455Upgrading Your Stove Single DoorAdvice on Handling and disposal of fire ceramics Fuel BED Arrangement104 Installation Details Flame Failure DeviceRunning ServicingInstallation Instructions Technical SpecificationQty Description Site Requirements Flue and Chimney RequirementsTimber Framed Buildings Rear Flue Installation Control UpgradeSafety Precautions Installation of the StoveTOP Exit TOP Flue UP and OUT KITTOP Flue Vertical Offset KIT ALL Fires TOP Flue UP and OUT with Additional BendOptional Extra Flue Lengths and Bends GAS SupplyNominal Actual Stainless Anthracite Canopy FittingFuel BED Arrangement 124 Commissioning CommissioningSERVICING/FAULT Finding Servicing InstructionsServicing Requirements Servicing Instructions Replacing Parts Main BurnerPilot Unit Ignition Lead Magnetic Safety Valve PiezoGAS Valve Main Injector Primary Aeration PlateChanging Between GAS Types Short Spares ListService Records 3RD Service 4TH Service

8456, 8455 specifications

The Yeoman 8455 and 8456 are significant advancements in the field of agricultural machinery, specifically designed to enhance productivity and efficiency for modern farming operations. These models exemplify innovation, boasting a range of features and technologies tailored to meet the diverse needs of farmers.

One of the main features of the Yeoman 8455 and 8456 is the robust construction, ensuring durability and longevity in various farming conditions. These machines are engineered with high-quality materials that withstand heavy use, reducing maintenance costs and downtime. The design also incorporates a user-friendly interface, making it accessible for operators with different levels of experience.

In terms of technology, the Yeoman series offers precision agriculture capabilities. Equipped with advanced GPS and mapping systems, these machines allow farmers to optimize their fieldwork by providing highly accurate planting and harvesting patterns. This technology not only improves yield but also contributes to sustainable farming practices by minimizing waste and maximizing efficiency.

The Yeoman 8455 and 8456 feature powerful engines that produce high torque, enabling them to perform well in challenging terrains. This strength is complemented by an advanced hydraulic system, facilitating smoother operation and better control over attachments and implements. Farmers can easily attach various tools, such as plows, seeders, and cultivators, enhancing the versatility of these models.

Another critical characteristic of the Yeoman 8455 and 8456 is their exceptional fuel efficiency. These models are designed to consume less fuel without compromising performance, which is especially important in today’s economy. The integration of eco-friendly technologies also helps reduce the environmental impact of farming operations, aligning with the global push towards sustainability.

Additionally, the comfort and ergonomics of the operator cabin are significant selling points. Both models are equipped with adjustable seating, climate control, and intuitive control panels, ensuring that operators can work for extended periods with minimal fatigue. Furthermore, enhanced visibility from the cabin allows for safer operation, particularly in crowded or intricate field settings.

In conclusion, the Yeoman 8455 and 8456 stand out as exemplary pieces of equipment in the agricultural industry. Their combination of robust construction, advanced technology, fuel efficiency, and operator comfort positions them as valuable assets for modern farmers looking to improve their productivity and sustainability in an increasingly competitive market.