Yeoman 8455, 8456 manual Optional Extra Flue Lengths and Bends, GAS Supply, Canopy Fitting

Page 15

INSTALLATION INSTRUCTIONS

INSTALLATION

9.OPTIONAL EXTRA FLUE LENGTHS AND BENDS

Nominal

Actual

Stainless

Anthracite

Length

Length

Finish

Finish

 

 

 

 

200mm

140mm

8527

8527AN

 

 

 

 

500mm

440mm

8528

8528AN

 

 

 

 

1000mm

940mm

8507

8507AN

 

 

 

 

40° Bend

N/A

8507

8507AN

 

 

 

 

90° Bend

N/A

8508

8508AN

 

 

 

 

Optional Flue Collar

N/A

8548

(Stoves Only)

 

 

 

 

 

 

Canopy Fitting

3.3To fit the canopy to the top of the stove:

• Slide the canopy over the top plate, Diagram 4

4

AR1937

Make sure the stove top fits into the guide along the bottom of the canopy, Diagram 5

5

AR1938

Push the canopy back until it hits the stop

Make sure the canopy sits square on top of the stove

4.GAS SUPPLY

4.4• Run the gas supply to the stove and PURGE THE SUPPLY PIPE. This is essential to expel any debris that may block the gas controls.

Connect the gas supply to the 8mm compression elbow at the right-hand rear corner of the stove

Check the gas soundness up to the gas inlet connection

Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening. If there is a definite flow into the chimney, carry on with the installation. If not, repeat after warming the chimney for a few minutes.

IF THERE IS STILL NO DEFINITE FLOW, THE FLUE MAY REQUIRE ATTENTION - SEEK EXPERT ADVICE

4.5The flue system can now be connected to the stove:

Make sure all joints are sealed with a suitable fire resistant sealant. We advise you to use a physical retention method at the flue spigot joint using self-tapping screws.

4.6• Connect a suitable pressure gauge to the test point on the inlet fitting and turn on the gas

Light the stove and check all gas joints for gas soundness

Turn the stove to maximum and check the supply pressure is as stated on the databadge

Turn off the gas and replace the test point screw

Turn on the gas and check the test point for gas soundness

Advice on Handling and disposal of fire ceramics

The fuel effect and side panels in this stove are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.

Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking.

To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the stove before and after working on it. When servicing the stove it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste.

RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site.

Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material.

Image 15
Contents Dartmoor Contents Appliance Commissioning Checklist Flue Check PassGAS Check Turning the Stove OFF User InstructionsGeneral Lighting the StoveSingle Door Cleaning the FireStandard Remote Control Yeoman Part Number YM-8455 Upgrading Your StoveFuel BED Arrangement Advice on Handling and disposal of fire ceramics104 Servicing Installation DetailsFlame Failure Device RunningInstallation Instructions Technical SpecificationQty Description Site Requirements Flue and Chimney RequirementsTimber Framed Buildings Rear Flue Installation of the Stove InstallationControl Upgrade Safety PrecautionsTOP Flue UP and OUT KIT TOP ExitTOP Flue UP and OUT with Additional Bend TOP Flue Vertical Offset KIT ALL FiresCanopy Fitting Optional Extra Flue Lengths and BendsGAS Supply Nominal Actual Stainless AnthraciteFuel BED Arrangement 124 Commissioning CommissioningSERVICING/FAULT Finding Servicing InstructionsServicing Requirements Servicing Instructions Replacing Parts Main BurnerPilot Unit Ignition Lead Magnetic Safety Valve PiezoGAS Valve Primary Aeration Plate Main InjectorShort Spares List Changing Between GAS Types3RD Service 4TH Service Service Records

8456, 8455 specifications

The Yeoman 8455 and 8456 are significant advancements in the field of agricultural machinery, specifically designed to enhance productivity and efficiency for modern farming operations. These models exemplify innovation, boasting a range of features and technologies tailored to meet the diverse needs of farmers.

One of the main features of the Yeoman 8455 and 8456 is the robust construction, ensuring durability and longevity in various farming conditions. These machines are engineered with high-quality materials that withstand heavy use, reducing maintenance costs and downtime. The design also incorporates a user-friendly interface, making it accessible for operators with different levels of experience.

In terms of technology, the Yeoman series offers precision agriculture capabilities. Equipped with advanced GPS and mapping systems, these machines allow farmers to optimize their fieldwork by providing highly accurate planting and harvesting patterns. This technology not only improves yield but also contributes to sustainable farming practices by minimizing waste and maximizing efficiency.

The Yeoman 8455 and 8456 feature powerful engines that produce high torque, enabling them to perform well in challenging terrains. This strength is complemented by an advanced hydraulic system, facilitating smoother operation and better control over attachments and implements. Farmers can easily attach various tools, such as plows, seeders, and cultivators, enhancing the versatility of these models.

Another critical characteristic of the Yeoman 8455 and 8456 is their exceptional fuel efficiency. These models are designed to consume less fuel without compromising performance, which is especially important in today’s economy. The integration of eco-friendly technologies also helps reduce the environmental impact of farming operations, aligning with the global push towards sustainability.

Additionally, the comfort and ergonomics of the operator cabin are significant selling points. Both models are equipped with adjustable seating, climate control, and intuitive control panels, ensuring that operators can work for extended periods with minimal fatigue. Furthermore, enhanced visibility from the cabin allows for safer operation, particularly in crowded or intricate field settings.

In conclusion, the Yeoman 8455 and 8456 stand out as exemplary pieces of equipment in the agricultural industry. Their combination of robust construction, advanced technology, fuel efficiency, and operator comfort positions them as valuable assets for modern farmers looking to improve their productivity and sustainability in an increasingly competitive market.