| Installation Instructions |
these learned measurements, so that next time the system runs it knows where to start and stop.
Status Light Codes
There is a light on the front of the mechanism motor box that will tell through its pattern of flashes and colors what the mechanism is doing.
Status Indicator |
Figure 13
Normal Doors At Rest - The Status Light will be on steady green.
Normal Run Motion of Doors - The Status Light will flash in groups of 2 green followed by a pause. In normal run motion the doors on a Eubank mechanism have a variable speed. The doors will start slowly, accelerate to a fast speed, and then slow down before coming to a stop.
Doors Obstructed - The Status Light will flash in groups of 3 red followed by a pause. If the doors meet an obstruction they will sense the obstruction, stop momentarily, and move in the opposite direction for a few seconds.
obstruction and then activate the doors. They should return to normal run motion.
Doors Obstructed Both Ways - The Status Light will flash in groups of 4 red followed by a pause. Similar to Doors Obstructed but doors are prevented from moving in either direction.
doors. They should return to normal run motion.
Travel Too Far - The Status Light will flash in groups of 5 red followed by a pause. The motor is running but the doors are not moving.
track, or is the motor box bent, causing it to become uncoupled from the track?
Power Loss - The Status Light will be on solid red.
has been a power loss (due to an electrical storm, etc.). When next activated the doors will move at a slow speed to their full closed position. If the doors are already closed they will not move. The Status Light will return to solid green and the doors are ready for normal activation.
Optional Control Input Connections
Control Input- 8 position RJ 45 modular phone jack
Discrete control for use with 3rd party control.
•Position 8- Open
•Position 7- Stop
IR Receiver “Eye” input for Eubank, Inc. supplied external IR reciever only.
•Position 6 - V out
•Position 5 - Vcc, 5v
Radio Power for external RF reciever only.
•Position 4 - 24 VDC
Sequence control for use with 3rd party control.
•Position 3 - Sequence- Open, Stop, Close, Stop
•Position 2 - Common
Discrete control for use with 3rd party control.
•Position 1 - Close
Control Input on Front of Motor Box
Control Input |
Figure 14
NOTE: Making a momentary dry contact closure between the common and the open, closed, stop, or sequence will activate the system in that mode.
Control Input on Front of Motor Box
Figure 15
12