SAFETY CONSIDERATIONS

This device is marked with the international Caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic Compatibility).

Unpacking & Inspection

Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate the unit if damage is found.

This instrument is a panel mount device protected in accordance with Class I of EN 61010 (115/230 AC power connections). Installation of this instrument should be done by Qualified personnel. In order to ensure safe operation, the following instructions should be followed.

This instrument has no power-on switch. An external switch or circuit-breaker shall be included in the building installation as a disconnecting device. It shall be marked to indicate this function, and it shall be in close proximity to the equipment within easy reach of the operator. The switch or circuit-breaker shall not interrupt the Protective Conductor (Earth wire), and it shall meet the relevant requirements of IEC 947-1 and IEC 947-3 (International Electrotechnical Commission). The switch shall not be incorporated in the mains supply cord.

Furthermore, to provide protection against excessive energy being drawn from the mains supply in case of a fault in the equipment, an over-current protection device shall be installed.

The Protective Conductor must be connected for safety reasons. Check that the power cable has the proper Earth wire, and it is properly connected. It is not safe to operate this unit without the Protective Conductor Terminal connected.

Do not exceed voltage rating on the label located on the top of the

instrument housing.

Always disconnect power before changing signal and power connections.

Do not use this instrument on a work bench without its case for safety reasons.

Do not operate this instrument in flammable or explosive atmospheres.

Do not expose this instrument to rain or moisture.

Unit mounting should allow for adequate ventilation to ensure instrument does not exceed operating temperature rating.

Use electrical wires with adequate size to handle mechanical strain and power requirements. Install without exposing bare wire outside the connector to minimize electrical shock hazards.

EMC Considerations

Whenever EMC is an issue, always use shielded cables.

Never run signal and power wires in the same conduit.

Use signal wire connections with twisted-pair cables.

Install Ferrite Bead(s) on signal wires close to the instrument if EMC problems persist.

iii

Image 5
Contents User’sGuide Page Table of Contents List of Figures DIN Case Dimensions Exploded ViewSafety Considerations Page Reference Input for 3-WIRE Ratio Specifications Analog InputGeneral Information Noise RejectionAccuracy AT 25C PowerDigital Inputs ANALOG-TO-DIGITAL ConversionMechanical Mechanical Assembly and Installation Case DimensionsPanel Mounting Exploded ViewChanging Operating Voltage Power and SignalPower and Signal Connections USA Lamp Test Signal Inputs Decimal Point Selection ConfigurationVoltage Range Selection Calibration Solder Switch LocationsDrawings DUAL-SLOPE Conversion Page Page Page WARRANTY/DISCLAIMER Shop on line at omega.com

DP3001 specifications

The Omega DP3001 is a versatile and innovative device that caters to the needs of both professionals and hobbyists in various fields, especially those requiring precise data logging and measurement capabilities. This advanced instrument is designed for accuracy, reliability, and ease of use, making it an essential tool for engineers, researchers, and technicians.

One of the standout features of the Omega DP3001 is its high-resolution measurement capability. With a dual display, it allows users to monitor multiple parameters simultaneously. The device supports an expansive range of input types, including thermocouples, RTDs, and voltage inputs, making it adaptable to different measurement requirements. The user-friendly interface lets operators quickly navigate through settings and configurations, enhancing productivity in fast-paced environments.

The DP3001 is equipped with state-of-the-art data logging technologies, which enables continuous monitoring of various parameters over extended periods. The internal memory can store extensive datasets, allowing for later analysis and documentation. Users can easily download data via the USB interface or connect to a computer for further analysis using accompanying software. This seamless integration with PCs offers a convenient way to manage large volumes of data.

Durability is another hallmark of the Omega DP3001. Constructed with robust materials, it is designed to withstand challenging conditions, ensuring longevity even in demanding environments. The device features an IP rating for water and dust resistance, providing additional assurance for outdoor usage or in industrial applications.

The ability to calibrate the device ensures that it maintains accuracy over time. The Omega DP3001 supports user calibration, giving operators the ability to adjust measurements according to specific standards or requirements. This flexibility is crucial for maintaining high-quality data integrity in critical applications.

Power management is also considered in the design of the DP3001. The device can operate on batteries or through an external power source, providing users with the flexibility to use it in the field or in laboratory settings without worrying about power availability.

In summary, the Omega DP3001 stands out as a powerful tool for precise measurements in various applications. Its high resolution, versatile input options, robust data logging capabilities, durability, user calibration, and flexible power options make it an ideal choice for those seeking reliability and efficiency in their measurement tasks. Whether in research, industrial, or educational settings, the Omega DP3001 is a trusted partner for accurate data acquisition.