INSTALLATION MANUAL
FOR THE
KD135GX-LPU~KD245GX-LPB
OF
SOLAR PHOTOVOLTAIC POWER MODULES
Please read this manual carefully before installing the modules.
KYOCERA
1. INTRODUCTION
As the world leader in the development and application of high technology ceramic/silica materials, Kyocera offers a wide range of highly efficient and reliable crystalline silicon solar photovoltaic (PV) power modules. Kyocera began to extensively research PV technology in 1975 and commenced manufacturing operations in 1978. Since then, Kyocera has supplied millions of cells and modules throughout the world. With years of experience and
2. APPLICATIONS
3. WARNINGS & SAFETY
PV modules generate electricity when exposed to light. Arrays of many modules can cause lethal shock and burn hazards. Only authorized and trained personnel should have access to these modules. To reduce the risk of electrical shock or burns, modules may be covered with an opaque material during installation. Do not touch live terminals with bare hands. Use insulated tools for electrical connections. Do not use these modules for solar concentration.
PERMIT
・Before installing your PV system, contact local authorities to determine the necessary permits, installation and inspection requirements.
INSTALLATION AND OPERATION
・Systems should be installed by qualified personnel only. The system involves electricity, and can be dangerous if the personnel are not familiar with the appropriate safety procedures.
・Do not step on the module.
・Although
・The module frame is made of anodized aluminum, and therefore corrosion can occur if the module is subject to a
・
・Module support structures to be used to support
・Do not expose the back of the module to direct sunlight
・In Canada installation shall be in accordance with CSA C22.1, Safety Standard for Electrical Installations, Canadian Electrical Code, Part 1.
・When handle the modules, DO NOT HOLD THEM BY
SUPPORTING ONLY ONE SIDE OF THE LONG FRAME BECAUSE IT CAN CAUSE SEPARATION OF THE GLASS AND FRAME.
CAUTION
FIRE RATING
・In case of roof installation, PV module assembly shall be mounted on a fire resistant roof covering rated for the application.
GROUNDING
・Refer to “Grounding” section.
BATTERY
・When PV modules are used to charge batteries, the battery must be installed in a manner, which will ensure the performance of the system and the safety of its users.
Follow the battery manufacturer’s safety guidelines concerning installation, operation and maintenance recommendations. In general, the battery (or battery bank) should be kept away from people and animals. Select a battery site that is protected from sunlight, rain, snow, debris, and is well ventilated. Most batteries generate hydrogen gas when charging, which can be explosive. Do not light matches or create sparks near the battery bank. When a battery is installed outdoors, it should be placed in an insulated and ventilated battery case specifically designed for this purpose.
4. SITE SELECTION
In most applications,