3M 300cf manual Installation and Set-Up, Receiving And Handling, Machine Set-Up, Uncrated

Page 11

Installation and Set-Up

Receiving And Handling

After the machine has been uncrated, examine the case former for damage that might have occurred during transit. If damage is evident, file a damage claim immediately with the transportation company and also notify your 3M Representative.

Machine Set-Up

Important Read "Warnings", on page 12, before attempting to set up the case former for operation.

For future reference, record machine serial number on front cover of this manual in the space provided.

The following instructions are presented in the order recommended for setting up and installing the case former, as well as for learning the operating functions and adjustments. Following them step by step will result in your understanding of the machine and an installation in your production line that best utilizes the many features built into the case former. Refer to Figure 3-1 to identify the various components of the case former.

Note A tool kit consisting of metric open end and hex socket wrenches is provided with the machine. These tools should be adequate to set up the machine, however, other tools supplied by the customer will be required for machine maintenance.

1.Follow "Unpacking Instructions" label attached to corrugated packing cover.

Use appropriate material handling equipment to remove the machine from the pallet and move it into position.

Whenever the machine is lifted with a fork truck, insure that the forks span completely across the machine frame and do not contact any mechanism under the machine frame.

CAUTION – Machine weighs approximately 85 kg ]190 lbs]

uncrated.

2.Adjust machine bed height.

The case former is equipped with four adjustable legs that are located at the corners of the frame. The legs can be adjusted to obtain different conveyor bed heights from 610 mm [24.0 inch] minimum to 775 mm [30.5 inch] maximum.

Refer to Figure 2-1 and adjust the bed height as follows:

(a)Block up the machine frame to allow adequate leg adjustment.

(b)Loosen, but do not remove, two M8 x 16 mm socket screws in one leg. Adjust the leg length for the desired bed height. Retighten the two screws to secure the leg. Adjust all four legs equally.

Figure 2-1 – Bed Height Adjustment

3.Install case former in production line.

Refer to Figure 2-2 for installation set up. Case former bed must be level and equal or slightly higher than case sealer bed height.

Install mounting brackets as shown in Figure 2-2.

7

Image 11
Contents 3M-Matic 300cf Case Former To Our Customers Replacement PartsService and Parts Available Direct from Table of Contents Intended Use Contents 300cf Case Former Emergency Stop Label Important SafeguardsRam Adjust and Box Ejector Labels Specifications Machine Dimensions H12 H22 Uncrated Installation and Set-UpReceiving And Handling Machine Set-UpMounting Bracket Installation Pneumatic Connections This page is Blank 300cf Case Former Components OperationOperation Box Ejector Reset ButtonEmergency Stop Button Box Centering GuideAutomatic Operating Procedure Lubrication MaintenanceOr damage to the machine Cleaning of the Machine Pneumatic Diagram Pneumatic DiagramPage This page is Blank Labels Parts and Service InformationReplacement Parts Ordering Information and Service This page is Blank 300cf Case Former, Type Frame Assemblies Replacement Parts Illustrations and Parts ListThis page is Blank 300cf Case Former Frame Assemblies 300cf Case Former Ref. No 3M Part No Description 300cf Case Former Ref. No 3M Part No Description 300cf Case Former Ref. No 3M Part No Description 300cf Case Former Ref. No 3M Part No Description 300cf Case Former Ref. No 3M Part No Description 300cf Case Former Ref. No 3M Part No Description 120af-if Infeed Conveyor Safety and Information Labels Ref. No 3M Part No Description Qty 120af-if Safety and Information Labels