Pelco CCC1300H-2X, MCC1300H-2 operation manual Motorized Zoom Lenses

Page 8

5.Adjust the back focus.

a.Use an Allen wrench to loosen the back focus lock screw at the side of the camera.

b.Turn the lens mount to obtain the sharpest image on the monitor.

c.Turn the back focus locking ring clockwise to tighten.

NOTE: Do not over tighen the back focus lock screw. Over tightening the back focus lock screw can damage the threads on the mount of the lens.

MOTORIZED ZOOM LENSES

1.With the camera operating, position the camera to view an object at least 70 feet (25 m) away.

2.Set the lens in the following manner:

a.Set the lens iris to its widest usable opening.

b.Set the lens focus to the FAR position.

c.Adjust lens zoom to WIDE angle.

3.Adjust back focus until the object is in sharpest focus.

a.Use an Allen wrench to loosen the back focus lock screw at the side of the camera.

b.Turn the lens mount to obtain the sharpest image on the monitor.

c.Turn the back focus locking ring clockwise to tighten.

4.Move lens zoom to TELEPHOTO.

5.Zoom out all the way while observing the focus on the monitor (known as “tracking”). If the image stays in focus throughout the entire zoom range, the back focus is correct. Otherwise, repeat the process beginning with step 1.

8

Pelco Manual C1961M-B (3/01)

Image 8
Contents Page Contents Important Safeguards and Warnings Regulatory NoticesModels DescriptionLocation and Function of Parts Power Input Terminal ESC Electronic Sensitivity ControlBLC Backlight Compensation Eclipser FunctionPower Connections Video ConnectionsCable Type Maximum Distance RG6/UBack Focus Adjustment General Lens InformationLens Mounting Auto Iris LensesMotorized Zoom Lenses Camera Synchronization Eclipser Adjustment ThreEclp GraySpecifications Power SuppliesGeneral Electrical BNCWarranty and Return Information Revision History