DC IRIS LEVEL

Select this option to adjust the electronic properties of the DC drive auto iris lens to the auto iris electronic properties of the camera. Perform this procedure before using the camera or each time you change the lens.

To perform this procedure, complete the following steps:

1.Focus the camera (refer to Lens Focusing on page 25).

2.Aim the camera at a bright, flickerless scene.

3.Select DC IRIS LEVEL from the MAIN MENU.

4.Adjust the DC IRIS LEVEL value (for the best image). The range is -20 to 20; the default setting is -8.

5.Press the center of the button to save the value.

6.Exit the MAIN MENU.

FLICKERLESS

In some installations, the cycle of the fluorescent lights may interfere with the electronic iris shutter speed. Use this option to override the shutter speed. When enabled, the shutter speed is set to 1/100 (NTSC) or 1/120 (PAL).

Select ON or OFF. The default setting is OFF.

NOTE: This option appears when AUTO EXPOSURE is set to NORMAL or BLC.

AUTOMATIC GAIN CONTROL

Automatic gain control (AGC) automatically adjusts the image when the light level changes. Most scenes benefit from AGC operation.

Select LOW, HIGH, or OFF. The default setting is LOW.

DAY AND NIGHT

This feature specifies how the camera will switch between day (color) and night (B-W) operation.

Select one of the following day and night options:

AUTO: Switches the filter automatically as light conditions change. The D&N DETECTION and D&N FILTER LIMIT settings appear.

The camera switches from day to night when the AGC gain level reaches 22 dB. It switches from night to day when the AGC gain level reaches 16 dB.

When AUTO is selected, both the angle of view and the lighting conditions may cause the camera filters to switch constantly.

COLOR: Operates the camera in day mode.

BW:Operates the camera in night mode.

EXT:Enables an external signal to switch between day and night modes (refer to Connecting Day/Night Filter Control on page 14 for more information). The D&N DETECTION and D&N FILTER LIMIT become enabled. In some installations, this option may be more reliable than AUTO mode.

NOTE: When AGC is disabled, AUTO is not available; you can select only COLOR or B-W mode.

20

C2944M-F (1/09)

Image 20
Contents C10DN Series Camera Contents List of Illustrations List of Tables Graphic Symbol Explanation Important Safety Instructions Equipment Handling Precautions Regulatory NoticesOptional Accessories DescriptionModels Required ToolsCamera Layout Installation Wiring AN Auto Iris LensLens Mounting Mounting the LensConnecting Video Camera MountingTable A. Video Coaxial Cable Requirements Cable Type Maximum DistanceConnecting Power C10DN-7X Camera onlyConnecting AC Power Connecting DC Power Do not exceed the values listed in Table C Connecting DAY/NIGHT Filter ControlSignal Voltage Accessing the Setup Menus Navigating the MenuMove the button up or down Move the button left or rightSetup Menus Function SET Main Menu Pixel CorrectionExposure Settings Function SettingsProfiles ActiveEclipser Exposure SettingsAuto Exposure DC Iris Level FlickerlessAutomatic Gain Control DAY and NightFunction Settings Detect TimeFilter Limit Line SyncWhite Balance ChromaGamma SharpnessMasking TitleSystem Information Save AS CustomPixel Correction Lens Focusing Fixed focal length lens onlyVarifocal lens only Camera Synchronization Manual White Balance Calibration Specifications Operating Temperature Storage TemperatureOperating Humidity Storage HumidityProduct Warranty and Return Information