Pelco C2944M-F (1/09) manual Lens Focusing, Fixed focal length lens only

Page 25

Lens Focusing

After mounting the lens, you must focus your C10DN Series camera. You will adjust both the back focus (on the camera) and the fine focus (on the lens).

NOTE: The back focus has already been adjusted using a standard CS-mount lens. However, you might need to adjust it again to match the mounted lens.

1.Auto iris only: Cover the auto iris lens with a suitable neutral density (ND) filter; this opens the iris fully. For best results, use an ND3 filter.

2.Manual iris only: Open the iris completely. Figure 8 shows the manual iris, varifocal, and lens focus locking screws for a sample lens. Refer to your lens documentation for more information.

BACK FOCUS LOCKING SCREW

VARIFOCAL LOCKING SCREW

LENS FOCUS LOCKING SCREW

1.5 MM ALLEN WRENCH

MANUAL IRIS LOCKING SCREW

Figure 8. Lens Focus

3.If Automatic Gain Control (AGC) is set to OFF, set it to LOW or HIGH on the FUNCTION SETTINGS menu. AGC is set to LOW by default.

a.Display the FUNCTION SETTINGS menu.

b.Change AGC to either LOW or HIGH.

c.Select EXIT to save the AGC setting.

4.Aim the camera at the farthest object in the field of view. Make sure it is at least 6.5 ft (2 m) away.

5.Fixed focal length lens only:

a.Set the lens focal length to far ().

b.Adjust the back focus.

c.Use a 1.5-mm Allen wrench to loosen the back focus locking screw.

d.Turn the lens until the image is focused. Tighten the back focus locking screw clockwise.

WARNING: Do not overtighten the back focus locking screw because you may damage the camera. (Back focus is a coarse adjustment. You will make the fine focus adjustment in the next step.)

e.Adjust the lens focus to achieve the best fine focus.

C2944M-F (1/09)

25

Image 25
Contents C10DN Series Camera Contents List of Illustrations List of Tables Graphic Symbol Explanation Important Safety Instructions Regulatory Notices Equipment Handling PrecautionsDescription Optional AccessoriesModels Required ToolsCamera Layout Wiring AN Auto Iris Lens InstallationLens Mounting Mounting the LensCamera Mounting Connecting VideoTable A. Video Coaxial Cable Requirements Cable Type Maximum DistanceC10DN-7X Camera only Connecting PowerConnecting AC Power Connecting DC Power Signal Voltage Connecting DAY/NIGHT Filter ControlDo not exceed the values listed in Table C Navigating the Menu Accessing the Setup MenusMove the button up or down Move the button left or rightFunction SET Setup MenusPixel Correction Main MenuFunction Settings Exposure SettingsProfiles ActiveAuto Exposure Exposure SettingsEclipser Flickerless DC Iris LevelAutomatic Gain Control DAY and NightDetect Time Function SettingsFilter Limit Line SyncChroma White BalanceGamma SharpnessTitle MaskingPixel Correction Save AS CustomSystem Information Fixed focal length lens only Lens FocusingVarifocal lens only Camera Synchronization Manual White Balance Calibration Specifications Storage Temperature Operating TemperatureOperating Humidity Storage HumidityProduct Warranty and Return Information