262260-YTG-E-1008

TABLE 4: DH 180 COOLING CAPACITIES (15 TON)

AIR ON

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

75°F

 

 

 

 

 

 

 

85°F

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL

 

TOTAL

POWER

 

SENSIBLE CAPACITY, MBH

 

TOTAL

POWER

 

SENSIBLE CAPACITY, MBH

 

 

 

ENTERING DRY BULB, °F

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

CFM

 

WB

MBH

KW

90

85

80

75

70

65

MBH

KW

90

85

80

75

70

65

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

223.0

11.3

100.4

79.0

57.7

-

-

-

218.1

12.9

99.3

77.9

56.5

-

-

-

 

 

72

211.0

11.2

133.1

111.7

90.3

68.9

-

-

203.0

12.6

130.5

109.2

87.8

66.4

-

-

4500

 

67

199.0

11.1

165.8

144.4

123.0

101.6

80.2

-

188.0

12.3

161.8

140.4

119.0

97.6

76.2

-

 

 

62

181.3

10.8

181.3

178.6

157.3

135.9

114.5

93.1

173.0

12.1

173.0

169.9

148.5

127.2

105.8

84.4

 

 

57

178.5

10.5

178.5

179.1

162.3

140.9

119.6

98.2

170.1

12.1

170.1

170.1

151.1

129.7

108.3

86.9

 

 

77

231.5

11.3

107.2

87.6

62.3

-

-

-

225.0

12.9

112.3

87.0

61.8

-

-

-

 

 

72

219.0

11.2

148.2

122.9

97.7

72.4

-

-

209.5

12.6

146.4

121.2

95.9

70.6

-

-

5250

 

67

206.5

11.2

189.2

158.3

133.0

107.7

82.5

-

194.0

12.4

180.5

155.3

130.0

104.7

79.5

-

 

 

62

188.1

10.9

188.1

186.8

170.1

144.9

119.6

94.3

178.5

12.2

178.5

177.0

162.3

137.0

111.7

86.5

 

 

57

185.3

10.6

185.3

185.5

175.7

150.4

125.1

99.8

175.6

12.2

175.6

175.6

165.0

139.8

114.5

89.2

 

 

77

240.0

11.4

114.0

96.2

67.0

-

-

-

232.0

13.0

125.3

96.2

67.0

-

-

-

 

 

72

227.0

11.3

163.3

134.2

105.0

75.8

-

-

216.0

12.7

162.3

133.2

104.0

74.8

-

-

6000

 

67

214.0

11.2

212.6

172.2

143.0

113.8

84.7

-

200.0

12.4

199.3

170.2

141.0

111.8

82.7

-

 

 

62

195.0

10.9

195.0

195.0

183.0

153.8

124.7

95.5

184.0

12.2

184.0

184.0

176.0

146.8

117.7

88.5

 

 

57

192.0

10.6

192.0

192.0

189.0

159.8

130.7

101.5

181.0

12.2

181.0

181.0

179.0

149.8

120.7

91.5

 

 

72

226.4

11.2

178.0

144.8

111.6

78.4

-

-

217.6

12.8

176.0

142.7

109.5

76.3

-

-

6750

 

67

213.5

11.2

212.8

185.2

152.0

118.8

85.6

-

201.5

12.5

201.2

181.7

148.5

115.3

82.1

-

 

62

194.5

10.8

194.5

194.5

188.5

155.3

122.1

88.9

185.4

12.2

185.4

185.4

181.4

148.2

115.0

81.8

 

 

 

 

57

191.5

10.5

191.5

191.5

190.0

156.8

123.6

90.4

182.4

12.2

182.4

182.4

181.4

148.1

114.9

81.7

 

 

72

225.8

11.2

192.8

155.5

118.2

81.0

-

-

219.2

12.8

189.6

152.3

115.1

77.8

-

-

7500

 

67

213.0

11.1

213.0

198.3

161.0

123.7

86.5

-

203.0

12.5

203.0

193.3

156.0

118.7

81.5

-

 

62

194.0

10.8

194.0

194.0

194.0

156.7

119.5

82.2

186.8

12.3

186.8

186.8

186.8

149.5

112.2

75.0

 

 

 

 

57

191.0

10.5

191.0

191.0

191.0

153.8

116.5

79.3

183.7

12.3

183.7

183.7

183.7

146.5

109.2

71.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR ON

 

 

 

 

 

TEMPERATURE OF AIR ON CONDENSER COIL

 

 

 

 

 

 

 

 

95°F

 

 

 

 

 

 

 

105°F

 

 

 

 

EVAPORATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL

 

TOTAL

POWER

 

SENSIBLE CAPACITY, MBH

 

TOTAL

POWER

 

SENSIBLE CAPACITY, MBH

 

 

 

ENTERING DRY BULB, °F

 

 

ENTERING DRY BULB, °F

 

 

 

 

CAP.1

INPUT2

 

 

CAP.1

INPUT2

 

 

CFM

 

WB

MBH

KW

90

85

80

75

70

65

MBH

KW

90

85

80

75

70

65

 

°F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

77

213.2

14.5

98.2

76.8

55.4

-

-

-

198.8

16.1

97.0

75.6

54.2

-

-

-

 

 

72

195.1

14.0

128.0

106.6

85.2

63.8

-

-

182.7

15.4

125.1

103.7

82.4

61.0

-

-

4500

 

67

177.0

13.5

157.8

136.4

115.0

93.6

72.2

-

166.5

14.8

153.3

131.9

110.5

89.1

67.7

-

 

 

62

164.6

13.4

164.6

161.2

139.8

118.4

97.1

75.7

155.6

14.7

155.6

153.8

135.7

114.3

93.0

71.6

 

 

57

161.8

13.7

161.8

161.2

139.8

118.4

97.1

75.7

152.2

15.0

152.2

151.9

134.0

112.6

91.3

69.9

 

 

77

218.6

14.5

117.4

86.5

61.2

-

-

-

203.9

16.2

117.3

84.6

59.4

-

-

-

 

 

72

200.0

14.0

144.7

119.4

94.1

68.8

-

-

187.3

15.5

140.7

115.5

90.2

64.9

-

-

5250

 

67

181.5

13.6

171.9

152.3

127.0

101.7

76.5

-

170.8

14.8

164.1

146.3

121.0

95.7

70.5

-

 

 

62

168.8

13.5

168.8

167.1

154.4

129.1

103.9

78.6

159.5

14.8

159.5

158.7

148.6

123.3

98.1

72.8

 

 

57

165.9

13.7

165.9

165.6

154.4

129.1

103.9

78.6

156.1

15.1

156.1

156.0

146.8

121.5

96.2

70.9

 

 

77

224.0

14.6

136.6

96.2

67.0

-

-

-

209.0

16.3

137.6

93.7

64.5

-

-

-

 

 

72

205.0

14.1

161.3

132.2

103.0

73.8

-

-

192.0

15.6

156.3

127.2

98.0

68.8

-

-

6000

 

67

186.0

13.6

186.0

168.2

139.0

109.8

80.7

-

175.0

14.9

175.0

160.7

131.5

102.3

73.2

-

 

 

62

173.0

13.5

173.0

173.0

169.0

139.8

110.7

81.5

163.5

14.9

163.5

163.5

161.5

132.3

103.2

74.0

 

 

57

170.0

13.8

170.0

170.0

169.0

139.8

110.7

81.5

160.0

15.2

160.0

160.0

159.5

130.3

101.2

72.0

 

 

72

208.9

14.3

173.9

140.7

107.4

74.2

-

-

195.8

15.7

170.2

137.0

103.8

70.6

-

-

6750

 

67

189.5

13.8

189.5

178.2

145.0

111.8

78.6

-

178.5

15.0

178.5

170.1

139.3

106.0

72.8

-

 

62

176.3

13.6

176.3

176.3

174.3

141.0

107.8

74.6

166.8

15.0

166.8

166.8

165.8

132.6

99.4

66.1

 

 

 

 

57

173.2

14.0

173.2

173.2

172.7

139.5

106.3

73.1

163.2

15.3

163.2

163.2

163.0

129.7

96.5

63.3

 

 

72

212.7

14.4

186.4

149.2

111.9

74.6

-

-

199.7

15.9

184.1

146.8

109.6

72.3

-

-

7500

 

67

193.0

13.9

193.0

188.3

151.0

113.7

76.5

-

182.0

15.2

182.0

179.6

147.0

109.7

72.5

-

 

62

179.5

13.8

179.5

179.5

179.5

142.3

105.0

67.7

170.0

15.1

170.0

170.0

170.0

132.8

95.5

58.3

 

 

 

 

57

176.4

14.1

176.4

176.4

176.4

139.1

101.9

64.6

166.4

15.5

166.4

166.4

166.4

129.1

91.9

54.6

10

Johnson Controls Unitary Products

Page 10
Image 10
York DH 300, DH 210, DH 240 warranty DH 180 Cooling Capacities 15 TON, CAP.1 INPUT2 CFM MBH

DH 240, DH 300, DH 180, DH 210 specifications

York International is known for its innovative and efficient HVAC systems, particularly their range of air conditioning units including the York DH series, comprising models DH 240, DH 300, DH 180, and DH 210. These units reflect state-of-the-art technology designed for optimal performance, energy efficiency, and reliability in diverse applications.

The York DH 240 is a versatile unit engineered for medium to large spaces. It features a compact design while delivering robust cooling performance. The incorporation of advanced inverter technology allows for precise temperature control and enhanced energy savings. Additionally, this model boasts an intelligent control system that ensures optimal operation based on real-time load conditions, further conserving energy.

The DH 300 model is designed for larger installations and offers unmatched cooling capacity. Its high-efficiency scroll compressors and variable speed fans minimize energy consumption, making it a wise choice for environmentally conscious businesses. Moreover, this unit includes a sophisticated microprocessor control system that facilitates monitoring and maintenance, ensuring peak operational efficiency throughout its lifespan.

The York DH 180 is tailored for smaller commercial applications where space is a premium. Its lightweight, low-profile design allows for easy installation while not compromising on performance. The DH 180 incorporates advanced filtration technology, ensuring high indoor air quality. With user-friendly digital controls, this unit can be customized to meet specific climate requirements.

Finally, the DH 210 offers a balanced solution for mid-range cooling needs with features that promote sustainability and efficiency. The unit is equipped with ecologically friendly refrigerants that comply with the latest environmental regulations. The incorporation of multi-stage filtration in the DH 210 ensures clean air delivery while reducing operational costs due to improved airflow design.

Collectively, the York DH series distinguishes itself through a commitment to quality, efficiency, and innovation. Each model, whether DH 240, DH 300, DH 180, or DH 210, is designed with advanced technology that prioritizes user experience and environmental sustainability. York's dedication to robust engineering ensures that these models not only meet but exceed the demands of modern commercial air conditioning needs, providing reliable solutions for diverse operational challenges.