262260-YTG-E-1008

available for single enthalpy and differential enthalpy configurations, respectively).

The rainhood is painted to match the basic unit and must be field-assembled before installing.

POWER EXHAUST - Our economizer options are avail- able with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. BAS- ready economizer actuators have an adjustable auxiliary end-switch to provide a range of damper positions available to energize power exhaust. For units with optional VAV, power exhaust is energized by means of a binary output signal from the unit's VAV control board.

The exhaust fan, motor and controls are installed and wired at the factory. The rain hood must be assembled and installed in the field.

The power exhaust option can only be used on bot- tom duct configurations.

MOTORIZED OUTDOOR AIR INTAKE DAMPER - Includes a slide-in /plug-in damper assembly with a 2- position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is oper- ating and will drive fully closed when the blower unit shuts down.

The rain hood is painted to match the basic unit and must be field assembled before installing.

BAROMETRIC RELIEF DAMPER - This damper option can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct.

PHENOLIC COATED EVAPORATOR AND CON- DENSER COILS - Special coating process that utilizes Technicoat 10-1" processes. Coating is applied by total immersion of the complete coil for maximum protection.

ELECTRIC HEATERS wired for single point power sup- ply. These nickel chromium heater elements are pro- vided with limit and automatic reset capability to prevent operation at excessive temperatures.

VARIABLE AIR VOLUME (VAV) - A factory-installed variable frequency drive (VFD), mounted in the Blower Access compartment, is used to control the speed of the indoor blower motor in order to maintain a constant static pressure in the supply duct. A pressure transducer and VAV control board are mounted inside the control box. The drive comes completely wired and pre-programmed from the factory.

An optional, factory-installed manual bypass switch available with factory-installed VFD can be found in the

Blower Motor Access compartment. The switch can be used to either route power to the VFD for modulating control of the blower motor, to bypass the drive and oper- ate the motor at full speed, or to power the drive (and not the motor) for diagnostic purposes.

Due to space limitations, VAV is not available with any of the factory-installed BAS options described below, but is available with ‘BAS-ready’ models. Terminal blocks are provided in the control box for field wiring of the cus- tomer-installed BAS.

A ‘VFD-ready’ option provides the provisions for a cus- tomer-installed drive. The unit comes with a mounting bracket installed in the Blower Access compartment which may accommodate other vendor’s drives depend- ing on their size. In order to utilize the unit’s mounting bracket, the maximum recommended drive dimensions are as follows:

For 5-hp motor applications

10” H x 6” W x 7” D

For 7.5 thru 15-hp motor applications

13” H x 8” W x 8” D

If the drive will not fit in the allotted space, then it will have to be mounted elsewhere; either within the building on a perpendicular wall which is not subjected to exces- sive temperature, vibration, humidity, dust, corrosive gas, explosive gas, etc., or within an appropriate enclo- sure rated for outside installation to safeguard against moisture, dust and excessive heat.

A terminal block located in the control box is provided for field connection of the VFD controls.

HOT GAS BYPASS - To allow for low cooling load oper- ation, a direct-acting pressure-modulating bypass control valve installed on the system #1 discharge line is used to divert high temperature, high pressure refrigerant around the TXV in order to maintain a desired minimum evapo- rator pressure. HGBP is standard on all units with VAV and optional with CV units.

FILTER OPTIONS - Standard units are shipped with 2” throw-away filters installed. 2” pleated and 4” pleated fil- ters are offered as a factory installed option.

CONVENIENCE OUTLET - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or you may order the unit with a “non-powered” conve- nience outlet that can be wired in the field.

DISCONNECT SWITCH - A HACR breaker sized to the unit max fuse size is provided. Factory installed option only.

BAS - Building Automation System Controls (avail- able on two-system cooling product only).

Simplicity® INTELLI-Comfort™ CONTROL - The York® Simplicity® INTELLI-Comfort™ control is factory installed. It includes a supply air sensor, a return air sen- sor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving

6

Johnson Controls Unitary Products

Page 6
Image 6
York DH 300, DH 210, DH 180, DH 240 warranty Johnson Controls Unitary Products

DH 240, DH 300, DH 180, DH 210 specifications

York International is known for its innovative and efficient HVAC systems, particularly their range of air conditioning units including the York DH series, comprising models DH 240, DH 300, DH 180, and DH 210. These units reflect state-of-the-art technology designed for optimal performance, energy efficiency, and reliability in diverse applications.

The York DH 240 is a versatile unit engineered for medium to large spaces. It features a compact design while delivering robust cooling performance. The incorporation of advanced inverter technology allows for precise temperature control and enhanced energy savings. Additionally, this model boasts an intelligent control system that ensures optimal operation based on real-time load conditions, further conserving energy.

The DH 300 model is designed for larger installations and offers unmatched cooling capacity. Its high-efficiency scroll compressors and variable speed fans minimize energy consumption, making it a wise choice for environmentally conscious businesses. Moreover, this unit includes a sophisticated microprocessor control system that facilitates monitoring and maintenance, ensuring peak operational efficiency throughout its lifespan.

The York DH 180 is tailored for smaller commercial applications where space is a premium. Its lightweight, low-profile design allows for easy installation while not compromising on performance. The DH 180 incorporates advanced filtration technology, ensuring high indoor air quality. With user-friendly digital controls, this unit can be customized to meet specific climate requirements.

Finally, the DH 210 offers a balanced solution for mid-range cooling needs with features that promote sustainability and efficiency. The unit is equipped with ecologically friendly refrigerants that comply with the latest environmental regulations. The incorporation of multi-stage filtration in the DH 210 ensures clean air delivery while reducing operational costs due to improved airflow design.

Collectively, the York DH series distinguishes itself through a commitment to quality, efficiency, and innovation. Each model, whether DH 240, DH 300, DH 180, or DH 210, is designed with advanced technology that prioritizes user experience and environmental sustainability. York's dedication to robust engineering ensures that these models not only meet but exceed the demands of modern commercial air conditioning needs, providing reliable solutions for diverse operational challenges.