GUIDE SPECIFICATIONS

GENERAL

Units shall be manufactured by Unitary Products in an ISO 9001 certified facility.

York's Sunline Ultra™ units are convertible single package units. All models have dual independent refrigerant circuits for efficient part load operation and maximum comfort con- trol. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory- mounted options and field-installed accessories to make them suitable for almost every application. All units are self- contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, replace the supply and return air panels on the rear of the unit with a side duct flange accessory. All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. A high static drive option is available for applications with a higher CFM and/or static pressure requirement.

Each unit shall have 2 condenser fan motors. All compres- sors include crankcase heat and internal pressure relief. Every refrigerant circuit includes an expansion valve, a liq- uid line filter-drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24-volt circuit breaker and a relay board with two compressor lockout circuits, a terminal strip for thermo- stat wiring, plus an additional set of pin connectors to sim- plify the interface of additional field controls. All models are CSA approved. All models include a 1-year limited warranty on the complete unit. Compressors and electric heater ele- ments carry an additional 4-year warranty. Aluminized steel tubular heat exchangers carry an additional 9-year warranty.

DESCRIPTION

Units shall be factory-assembled, single packaged, DH***N Electric Cooling/Gas Heat, DH***C/E Electric Cooling/ Optional Electric Heat, designed for outdoor mounted instal- lation. The 15 ton units shall have minimum EER ratings of 10.8, the 17.5 ton units shall have minimum EER ratings of 10.2, the 20 ton units shall have minimum EER ratings of 9.7 and the 25 ton units shall have minimum EER ratings of 9.6.

They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge

262260-YTG-E-1008

supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both num- bered and color coded. All units shall be manufactured in a facility certified to ISO 9001 standards and the cooling per- formance shall be rated in accordance with DOE and ARI test procedures. Units shall be CSA listed, classified to ANSIZ21.47 standards, UL 1995/CAN/CSA No. 236-M90 conditions.

UNIT CABINET

Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non-chalking, powdered paint finish, certified at 1000 hour salt spray test per ASTM- B117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to pre- vent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 2" fil- ters shall be furnished and be accessible through a remov- able access door, sealed airtight. Units filter track shall be designed to accommodate either 2" or 4" filters. Fan perfor- mance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evapora- tor fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self-draining stan- dards. Condensate connection shall be a minimum of 1" I.D. female and be a ridged mount connection. Unit shall incor- porate a fixed outdoor air damper with an outdoor air intake opening covered with a bird screen and a rain hood painted to match the exterior of the unit.

INDOOR (EVAPORATOR) FAN ASSEMBLY

Fan shall be a belt drive assembly and include an adjustable- pitch motor pulley. Job site selected (B.H.P.) brake horse- power shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double-inlet type with forward-curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume.

A variable air volume (VAV) option using a variable frequency drive (VFD) is available for applications requiring a constant supply duct static pressure. Units equipped for VAV shall be controlled by a duct pressure transducer with a 0 - 5” WC pres- sure range. The pressure transducer shall provide a 0 - 5 VDC output signal to a VAV control board which, in turn shall provide a 2 - 10 VDC speed reference signal to the VFD. The VAV control board shall operate using factory-installed Supply Air, Return Air and Outside Air Temperature Sensors. Units equipped with VFD’s shall have factory-installed manual bypass as an option.

Johnson Controls Unitary Products

41

Page 41
Image 41
York DH 180, DH 210, DH 300, DH 240 warranty Guide Specifications, General, Description

DH 240, DH 300, DH 180, DH 210 specifications

York International is known for its innovative and efficient HVAC systems, particularly their range of air conditioning units including the York DH series, comprising models DH 240, DH 300, DH 180, and DH 210. These units reflect state-of-the-art technology designed for optimal performance, energy efficiency, and reliability in diverse applications.

The York DH 240 is a versatile unit engineered for medium to large spaces. It features a compact design while delivering robust cooling performance. The incorporation of advanced inverter technology allows for precise temperature control and enhanced energy savings. Additionally, this model boasts an intelligent control system that ensures optimal operation based on real-time load conditions, further conserving energy.

The DH 300 model is designed for larger installations and offers unmatched cooling capacity. Its high-efficiency scroll compressors and variable speed fans minimize energy consumption, making it a wise choice for environmentally conscious businesses. Moreover, this unit includes a sophisticated microprocessor control system that facilitates monitoring and maintenance, ensuring peak operational efficiency throughout its lifespan.

The York DH 180 is tailored for smaller commercial applications where space is a premium. Its lightweight, low-profile design allows for easy installation while not compromising on performance. The DH 180 incorporates advanced filtration technology, ensuring high indoor air quality. With user-friendly digital controls, this unit can be customized to meet specific climate requirements.

Finally, the DH 210 offers a balanced solution for mid-range cooling needs with features that promote sustainability and efficiency. The unit is equipped with ecologically friendly refrigerants that comply with the latest environmental regulations. The incorporation of multi-stage filtration in the DH 210 ensures clean air delivery while reducing operational costs due to improved airflow design.

Collectively, the York DH series distinguishes itself through a commitment to quality, efficiency, and innovation. Each model, whether DH 240, DH 300, DH 180, or DH 210, is designed with advanced technology that prioritizes user experience and environmental sustainability. York's dedication to robust engineering ensures that these models not only meet but exceed the demands of modern commercial air conditioning needs, providing reliable solutions for diverse operational challenges.