<ALERT>
ALERT |
|
|
|
REPEAT | CONSTANT |
ACK ACTION | ALWAYS ON |
ACTIVATE AUX | NO |
<CURRENT READING> |
|
RESET ALERT |
|
BACK |
|
EXIT |
|
*These features are available only on Spectra III SE Series dome systems.
The Alert menu applies only to pressurized dome systems.
Sensors strategically placed inside the pressurized dome system continually monitor pressure, temperature, and dew point. If internal conditions reach unacceptable levels, an alert message appears on the screen describing the alert condition. Example: If pressure drops below 1 psig, “LOW PRESSURE” is displayed on the monitor.
The alert message will be repeatedly displayed until the system controller acknowledges the alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message changes to the programmed acknowledge action (ACK ACTION). If the alert condition remains active after a period of time, the alert message reappears on the monitor, restarting the alert message cycle. This cycle will continue to repeat until the alert condition is resolved.
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system controller acknowledges the alert condition. The following are the settings for REPEAT:
CONSTANT - The alert message is continuously displayed on the monitor until acknowl- edged.
15 MIN - The alert message is displayed every 15 minutes for a
30 MIN - The alert message is displayed every 30 minutes for a
60 MIN - The alert message is displayed every 60 minutes for a