3.2 CONNECTOR ASSEMBLY
NOTE: Contacts cannot be removed from the connector without the use of an AMP extraction tool, part num- ber ZT305183 (for
To install and test the SS2000/SS2002 Series dome you will need to assemble the connector parts provided. Fabricate the interconnecting cable as outlined below (see Figure 5):
1.Slide the cable clamp (part A , item 1) over the cable with the threaded end facing the connector (item 5).
2.If the cable has a diameter less than 1/2 inch (1.3 cm), slide the rubber boot (item 2) over the end of the cable and press inside the cable clamp to form a good seal.
3.Strip back the cable jacket approximately
4.The contact pins supplied with the mating connector are the “crimp” type which may also be soldered if you so desire.
5.After crimping or soldering the contacts, push them into the proper holes in the connector until they snap in place.
6.Slide part A of the cable clamp toward the connector and screw the parts together. Attach part B (item 1) onto part A and connect both parts with the screws provided.
7.Connect the cable assembly to the unit and seat the connector by twisting the locking collar until it snaps into position.
8.For ease of installation, a mating cable assembly is supplied with the domes to extend the cable from the pan/tilt. Please refer to Figures 6 and 7 for wiring (pin locations and color codes).
Figure 5. Connector Assembly
Pelco Manual | 9 |