3.0 INSTALLATION
Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair.
3.1 CONDUCTOR AND CABLE REQUIREMENTS
NOTE: The following are cable re- quirements. A relay box (RB24) is available to extend the operating dis- tance up to 13,000 feet (3,962 m) over 16 Awg wire.
A minimum of 11 conductors plus coax is required, which includes common re- quirements for motorized zoom lens and camera AC power.
Non-PP Models
| 11 Conductor | 12 Conductor* |
18 Awg | 227 ft (82m) | 494 ft (150 m) |
16 Awg | 432 ft (131 m) | 785 ft (239 m) |
14 Awg | 690 ft (210 m) | 1,253 ft (381 m) |
PP Models |
|
|
| 17 Conductor | 18 Conductor* |
18 Awg | 227 ft (82m) | 494 ft (150 m) |
16 Awg | 432 ft (131 m) | 785 ft (239 m) |
14 Awg | 690 ft (210 m) | 1,253 ft (381 m) |
* Using 2 conductors for common
Calculations are based on a 10% cable loss with both motors running.
3.1.1 Recommended Mounts
MRWA | Wall mount adapter |
MRCA | Ceiling mount adapter |
3.1.2 Recommended Cables
C1906 | Pretested |
C1925 | Pretested |
Pelco Manual | 5 |