Pelco SS2002, SS22, SS2000 operation manual Installation, Conductor and Cable Requirements

Page 5

3.0 INSTALLATION

Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair.

3.1 CONDUCTOR AND CABLE REQUIREMENTS

NOTE: The following are cable re- quirements. A relay box (RB24) is available to extend the operating dis- tance up to 13,000 feet (3,962 m) over 16 Awg wire.

A minimum of 11 conductors plus coax is required, which includes common re- quirements for motorized zoom lens and camera AC power.

Non-PP Models

 

11 Conductor

12 Conductor*

18 Awg

227 ft (82m)

494 ft (150 m)

16 Awg

432 ft (131 m)

785 ft (239 m)

14 Awg

690 ft (210 m)

1,253 ft (381 m)

PP Models

 

 

 

17 Conductor

18 Conductor*

18 Awg

227 ft (82m)

494 ft (150 m)

16 Awg

432 ft (131 m)

785 ft (239 m)

14 Awg

690 ft (210 m)

1,253 ft (381 m)

* Using 2 conductors for common

Calculations are based on a 10% cable loss with both motors running.

3.1.1 Recommended Mounts

MRWA

Wall mount adapter

MRCA

Ceiling mount adapter

3.1.2 Recommended Cables

C1906

Pretested 6-foot cable with video coax

C1925

Pretested 25-foot cable with video coax

Pelco Manual C429M-B (2/98)

5

Image 5
Contents Listed Contents General Important Safeguards and WarningsModels DescriptionConductor and Cable Requirements InstallationSS2000/SS2000-SL/SS2002-SL Wiring Diagram SS2000-PP Wiring Diagram SS2000SL-PP Wiring Diagram Connector Assembly Connector AssemblyConductor Cable Coax Mounting Mounting ConfigurationsDome Installation Table A. SS2000/SS2002 Exploded Assembly Diagram Exploded Assembly DiagramSS2000/SS2002 Exploded Assembly Diagram Limit Stop Locations AdjustmentsMaintenance Electrical SpecificationsGeneral Pelco Manual C429M-B 2/98 Warranty Warranty and Return Information