Pelco TI2550 manual Important Safety Instructions

Page 4

Important Safety Instructions

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

6.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

7.Only use attachments/accessories specified by the manufacturer.

8.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

9.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

10.Installation should be done only by qualified personnel and conform to all local codes.

11.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.

12.Use only installation methods and materials capable of supporting four times the maximum specified load.

13.Use stainless steel hardware to fasten the mount to outdoor surfaces.

14.To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the mount and mounting surface.

15.An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building.

16.A readily accessible disconnect device shall be incorporated in the building installation wiring.

17.Use only a UL Listed Class 2 power supply.

CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so.

Only use replacement parts recommended by Pelco.

After replacement/repair of this unit’s electrical components, conduct a resistance measurement between the line and exposed parts to verify the exposed parts have not been connected to the line circuitry.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION:

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

WARNING: This product is sensitive to Electrostatic Discharge (ESD). To avoid ESD damage to this product, use ESD safe practices during installation. Before touching, adjusting or handling this product, correctly attach an ESD wrist strap to your wrist and appropriately discharge your body and tools. For more information about ESD control and safe handling practices of electronics, please refer to ANSI/ESD S20.20-1999 or contact the Electrostatic Discharge Association (www.esda.org).

4

C1309M-A (9/08)

Image 4
Contents TI2500 Series Fixed-Mount Thermal Imager Contents List of Illustrations Important Safety Instructions Regulatory Notices Radio and Television InterferenceParts List DescriptionModels Qty DescriptionSetup Installing Software Minimum System RequirementsBench Setup Disassemble the EnclosureConnect Wiring RS-422 TX RS-422 TX+ RS-232 Not Used RS-422 RX+RS-422 RX RS-232 Not Used DescriptionInterfacing with a PC Reassemble the EnclosureField Setup Reassemble the Enclosure Configuration Camera TABStatus Perform Manual FFCChanging the Image Orientation Mode Video TABChanging the POLARITY/LUT Setting PAN and ZoomDynamic Detail Enhancement DDE PanAGC Mode AGC TABAGC Parameters Linear ParametersRegion of Interest About TAB TI25 GUI About TabInstallation Cable Type Maximum DistanceTroubleshooting Symptom ProblemMaintenance Cleaning the LensSpecifications ElectricalProduct Warranty and Return Information ISO9001

TI2550 specifications

The Pelco TI2550 is a state-of-the-art thermal imaging camera designed to enhance surveillance and security operations. It features advanced technology that enables users to detect and monitor heat signatures, making it an invaluable tool for various applications, including perimeter security, agricultural monitoring, and search and rescue missions.

One of the standout features of the Pelco TI2550 is its high-resolution thermal sensor, which provides exceptional image quality even in the most challenging environmental conditions. With a resolution of 640 x 480 pixels, this camera captures fine details and allows operators to identify objects and individuals concealed by darkness, fog, smoke, or dust. This capability is crucial for nighttime surveillance or situations where visibility is compromised.

The TI2550 boasts a robust thermal sensitivity that can detect temperature differences as small as 50 mK, enabling it to identify subtle heat signatures. This level of sensitivity not only enhances detection capabilities but also ensures a high rate of false alarm reduction, making it a reliable choice for security personnel.

For versatility in deployment, the Pelco TI2550 offers a variety of lens options. Users can choose from multiple focal lengths to suit their specific needs, whether they require wide-angle views for expansive areas or narrow views for distant targets. Additionally, the camera is equipped with continuous zoom capabilities, allowing for real-time adjustments to the field of view.

The TI2550 integrates seamlessly with existing security systems, featuring standard video outputs such as Analog and IP formats. This compatibility ensures that the camera can be easily incorporated into both new and pre-existing surveillance infrastructures. Furthermore, it supports advanced video analytics that can help in automatic detections, such as alarming on unusual temperature variations.

With a ruggedized design, the Pelco TI2550 is built to withstand harsh environmental conditions. It is rated for both dust and water resistance, making it suitable for outdoor applications. Its ability to operate in extreme temperatures ensures dependable performance in diverse settings, from arctic cold to desert heat.

In conclusion, the Pelco TI2550 stands out in the realm of thermal imaging technology. With its high resolution, exceptional sensitivity, versatile lens options, and robust design, it serves as an essential tool for enhancing situational awareness and operational effectiveness in security and surveillance tasks. The integration of advanced analytics further positions the TI2550 as a formidable asset in modern security applications.