Right Panel
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
|
|
|
| POWER |
|
|
|
|
|
| WARNING |
|
|
|
|
|
|
| THIS APPARATUS | OFF |
|
|
|
VF.2> | >VF.1 | >External | MUST BE EARTHED | REMOTE | LOCAL |
| |
|
|
|
|
| |||
|
|
| 230V AC T1.6A |
| VF (cam) | LENS (cam) | |
|
|
| 115V AC T4A |
|
|
1 Second viewer socket (VF2) | 5 Mains power supply On/Off switch |
A
Switches the mains power supply to the large lens adapter on or off. (It does not switch off the power to the utility outlet.)
2Video 1 input socket
A BNC socket which supplies a video signal for a monitor or a second viewer connected to the VF2 socket.
6Local / Remote power switch
Switches the large lens adapter to the local or remote power mode.
3CVBS input socket
A BNC socket which supplies a video signal for a monitor or a second viewer connected to the VF2 socket.
7Viewfinder flying lead
Connects the camera viewfinder signal and data bus to the large lens adapter (the large lens adapter passes the signal to the
4Mains power supply input (Local power)
Input voltage for NTSC version: 115 Vac (±15%) Fuse: 4A Slow, 250 Vac
Input voltage for PAL version: 230 Vac (±15%) Fuse: 1.6A Slow, 250 Vac
The frequency of the mains power supply must be between 47Hz and 63Hz.
8Lens flying lead
Connects the lens connector at the front of the large lens adapter to the camera.