Page 12
TM-6760 Series Progressive Scan Shutter Cameras
When wiring the
•The lead ends must be twisted together and
•Shrink tubing or a similar insulator should be used to prevent exposed leads from touching and shorting.
•The +12V lead is marked with a red stripe or white lettering; be sure not to reverse the leads.
•All connections must be properly insulated to prevent shorting.
2.2.7 (b) JAI, Inc. Power Cables
If you are using JAI, Inc. power cables such as the
FIGURE 7. 12P-02S Interface Cable (optional)
|
| +12 V | |
| GND (Gray) |
|
|
Jack | Power (Yellow) |
|
|
| Video Out (Red Coax) | } | |
| HD In (White Coax) |
| |
| VD In (Black Coax) |
|
Monitor
Analog
Frame Grabber
Pin# | Lead Color | Function | Pin# | Lead Color | Function |
|
|
|
|
|
|
1 | Gray | GND | 7 | Black coax | VD Input |
|
|
|
|
|
|
2 | Yellow | +12V DC | 8 | White coax shield | Reserved |
|
|
|
|
|
|
3 | Red coax shield | GND | 9 | White coax | HD Input |
|
|
|
|
|
|
4 | Red coax | Video | 10 | Brown | RXD |
|
|
|
|
|
|
5 | Orange coax | GND | 11 | Blue | Integration |
| shield |
|
|
|
|
|
|
|
|
|
|
6 | Orange coax | VINIT IN | 12 | Black coax shield | TXD |
|
|
|
|
|
|
Note: Make sure that the unused leads are not touching and that there is no possibility that exposed wires could cause the leads to short.
2.2.8Attaching the Analog Video Output
When connecting the
The
Note: Make sure that no extraneous wires are visible which could cause a short.
Installation