TM-6760 Series Progressive Scan Shutter Cameras
FIGURE 8. Pulse Width Async Shutter Timing
No Delay Shutter
EXT. VINIT (Pulse width control)
HD
INT. VINIT after trailing edge of EXT. VINIT
Discharge
Exposure time set by pulse width
Transfer Gate
FDV
41H
Analog Video Sync |
| Vsync | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3.6.2Internal Shutter Speed Control
The video signal starts with internal VINIT. The camera operates the reset and shutter in the same way as the external pulse width control mode. When the external VINIT pulse is applied, internal VINIT is latched to HD and the internal VINIT is delayed to set up the shutter speed period. The shutter speed is controlled by the dial switch from “1” to “8.” Video output timing starts right after the internal VINIT and single shots, FDV is output at the internal VINIT timing.
EXT. VINIT
HD
INT. VINIT with shutter speed control
Discharge
Exposure time set by shutter speed
Transfer Gate
FDV
41H
Analog Video Sync
Operation