EverFocus EHD320 user manual Wire Connection

Page 10

5. Wire Connection

Termination Board

Micro Switch for Alarm trigger

 

 

 

Power In

 

 

GND

DC12V (+) or AC24V

 

Alarm COM

 

 

Video

Power In

 

Alarm NO

 

V. Phase Adjustment VR

Alarm NC

AC12V (-)or AC24V

 

 

 

 

Figure 7

Connect the power supply cable (AC24V/DC12V), video output and alarm output to the proper connectors shown as Figure 7.

The V. Phase adjustment screw is located on the termination board. The vertical phase may require adjustment to synchronize the vertical phase of the camera with other camera in the system when it is to be used in the line-lock sync mode. Make the adjustment when the vertical phase of the camera does not match with other cameras.

7

Image 10
Contents EHD320 Page Table of Contents Cleaning Safety WarningDo not install the camera near electric or magnetic fields Never face the camera toward the sunIntroduction Specification YESInstallation Instructions Mounting the base Wall Wire Connection Lens fixing Screws LL Line-Lock Off/On AGC Automatic Gain Control Off/OnFL Flickerless Function On/Normal BLC Back Light Compensation On/NormalES Electronic Shutter Off/On Iris Level Adjustment Iris ALC AdjustmentEverFocus Electronics Corp