Samson 4060/4120 owner manual Guided Tour Rear Panel, Emc

Page 6

Guided Tour - Rear Panel

3

1

3

-

+

+

-

-

+

+

-

CAUTION

!

 

 

 

 

 

 

 

 

 

 

RISK OF ELECTRIC SHOCK

 

 

 

 

 

 

 

 

 

 

DO NOT OPEN

 

 

 

 

 

 

 

 

 

 

USE CLASS 2 WIRING

 

 

 

 

 

 

 

 

 

 

 

emc

 

-

+

4120W

+

-

 

-

+

+

-

 

 

CH4

CH3

AC USA & CANADA 115V - 60Hz

CH2

4120W

CH1

 

 

-

MAX. LOAD

+

INLET EUROPE & UK 230V - 50Hz

 

+

MAX. LOAD

 

 

 

 

MONO 8

 

650W MAX.

 

-

 

EUR . USA . JPN

 

 

 

 

CAUTION:

 

ATTENTION:

 

MONO 8

 

AVIS;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECT SUPPLY CORD

 

DEBRANCHER AVANT DE

 

 

 

RISQUE DE CHOC ELECTRIQUE

 

 

 

 

 

BEFORE CHANGING FUSE.

 

REMPLACER LE FUSIBLE.

 

 

 

NE PAS OUVRIR

BRIDGE

 

 

 

FOR CONTINUED PROTECTION

 

UTILISERUN FUSIBLE DE

 

 

 

DO NOT EXPOSE THIS EQUIPMENT

 

 

 

 

 

AGAINST RISK OF FIRE, REPLACE

 

RECHANGE DE MEM TYPE.

 

 

 

TO RAIN OR MOISTURE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ONLY WITH SAME TYPE OF FUSE.

USA & CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

ON

 

 

 

FUSE

T 8A/125V (115V)

 

 

 

 

 

 

 

CH4 R

 

CH3 R

EUROPE AND UK

 

CH2 L

 

CH1 L

 

 

 

 

 

 

 

 

 

 

 

 

T 6.3A/250V (230V)

 

 

 

 

 

 

 

 

 

 

 

 

 

SERVO 4120

QUAD AMPLIFIER

SERIAL NUMBER

SAMSON

SAMSON TECHNOLOGIES CORP., U.S.A.

BRIDGE

OFF ON

6

4

5

2

4

1: AC input - Connect the supplied standard 3-pin “IEC” plug here.

5

6

2:Fuse holder - In the Servo Quad 4060, insert an 6 amp, 125 volt fuse here for 115 volt operation, or a 3.15 amp, 250 volt fuse for 230 volt operation. In the Servo Quad 4120, insert an 8 amp, 125 volt fuse here for 115 volt operation, or a 6.3 amp, 250 volt fuse for 230 volt operation. We recommend the use of normal (as opposed to slow-blow) fuses. WARNING: Fuses should only be replaced with the power cord disconnected.

3:Binding post (banana jack) output connectors (Ch 1 - 4) - Use these to connect each channel of the Servo Quad Amplifier to loudspeakers. Be sure to connect the loudspeaker correctly, with the red

(+) terminal normally connected to the positive input of the speaker and the black (-) terminal normally connected to the negative input of the speaker. See the “Bridge Stereo Mode” section on page 7 in this manual for speaker connection instructions when using the Servo Quad Amplifier in bridge mode.

4:Balanced Inputs* (Ch 1 - 4) - Connect incoming signal to these electronically balanced 1/4" TRS (Tip/Ring/Sleeve) jacks, wired as follows: Tip hot, Ring cold, and Sleeve ground. Use balanced three- conductor cabling and TRS plugs wherever possible (unbalanced two-conductor plugs can also be inserted into these inputs, but you’ll get better signal quality and less outside noise and hum if you use balanced lines). Note that the Servo Quad Amplifier balanced inputs are 6 dB higher in gain than the balanced inputs (see #5 below). The Servo Quad Amplifier accepts input levels of any strength but needs at least 0 dBm to get maximum power.

5:Unbalanced Inputs* (Ch 1 - 4) - Connect incoming signal to these unbalanced RCA-type jacks. The Servo Quad Amplifier accepts input levels of any strength but needs at least 0 dBm to achieve maximum power. Note that the Servo Quad Amplifier unbalanced inputs are 6 dB lower in gain than the balanced inputs (see #4 above).

6:Bridge switch - For normal operation, place this switch at its left (“OFF”) position. When placed at its right (“ON”) position, each of the two amplifier sections (channel 1 and channel 2 and/or channel 3 and channel 4) are bridged, providing full 120 or 240 watt power output, depending upon the Servo Quad model you’re using. For more information, see the “Bridge Stereo Mode” section on page 7 in this manual. WARNING: Due to the extremely high power output of the Servo Quad Amplifier when used in Bridge Stereo mode, be sure to use only 8 ohm loudspeakers sufficiently rated to handle the resultant wattage.

* If required, both the balanced and unbalanced inputs can be used simultaneously.

6

Image 6
Contents Amplifier Introduction Servo Quad Amplifier Features Guided Tour Introduction Servo Quad Amplifier Features Guided Tour Front Panel SamsonGuided Tour Rear Panel EmcSetting Up and Using the Servo Quad Amplifier Servo Quad Amplifier Protection Circuitry Bridge Stereo Mode Input Channel + OutputBi-amplification Applications Appendix a Linearity vs. Frequency Sweep THDAppendix B Power Output vs. THD Specifications Rated Output Power, per channel

4060/4120 specifications

The Samson 4060/4120 series represents a robust line of industrial signalling devices designed to provide reliable alarm and indication systems across a myriad of applications. Engineered with precision and utility in mind, these products serve a pivotal role in safety and operational efficiency in industries ranging from manufacturing to hospitality.

One of the standout features of the Samson 4060/4120 series is its flexible configuration options. Users can easily tailor these devices to meet specific operational needs by adjusting settings such as alarm thresholds, tones, and volumes. This adaptability is further enhanced by compatibility with various power supplies, including AC and DC voltages, making them suitable for diverse environments.

In terms of technologies, the Samson 4060/4120 incorporates advanced digital signal processing (DSP), which ensures crystal-clear audio output. The DSP technology minimizes distortion and enhances sound quality, allowing the devices to produce loud, attention-grabbing signals that can be heard over ambient noise. Additionally, the series includes a wide array of alarm tones and patterns, providing clear differentiation for various alerts.

Durability is another hallmark of the Samson 4060/4120 devices. Constructed with high-quality materials, they are designed to withstand harsh conditions, including extreme temperatures, dust, and moisture. This ruggedness ensures that the devices remain operational in challenging environments, which is crucial for industries that cannot afford downtime.

The series also features easy installation and maintenance. With user-friendly interfaces and accessible wiring options, operators can quickly install and maintain the devices with minimal training. This simplicity reduces labor costs and enhances the overall efficiency of alarm system management.

Moreover, the Samson 4060/4120 series meets international safety standards, ensuring compliance with regulations across various sectors. This compliance provides peace of mind for businesses, knowing that they are utilizing equipment that adheres to strict safety protocols.

In summary, the Samson 4060/4120 series combines flexibility, advanced technology, and robust construction to deliver a reliable signalling solution. These devices not only enhance safety but also streamline operational processes, making them essential for industries that prioritize performance and reliability in their alarm and indication systems.