Philips LTC0500 installation manual Mechanical, Environmental

Page 11

MECHANICAL

 

Dimensions:

65 x 70 x 149 mm (HxWxD*) * including connectors

Weight:

0.6 kg

Camera mounting:

Top and Bottom 1/4” 20 UNC

Lens mounting:

C & CS

Lens weight:

0.5 kg top mounting, 1.5 kg bottom mounting

Power:

LTC 0500/10 & -/20: Screw terminals

LTC 0500/50: 2-strand power cable with Euro plug

LTC 0500/60: 2-strand power cable with polarized US plug Power supply input terminals are isolated from video output terminals

ENVIRONMENTAL

 

 

Temperature range:

 

 

Operating:

-10 to 55 ºC,

(14 to 131 ˚F)

Storage:

-40 to 70 ºC,

(-40 to 158 ˚F)

Operating Humidity:

5% to 93% non condensing

Electro-Magnetic Compatibility:

 

Emission:

EN 50081-1,

FCC Part 15 Class B

Immunity:

EN 50130-4

 

Safety:

LTC 0500/10 and /50: EN 60950

LTC 0500/20 and /60: UL 6500 and CSA -E65 - 94.

Accessories: Configuration Software LTC 0650/00, supporting Windows 3.x, Windows 95/98/NT

18

Image 11
Contents Digital Black & white Camera Contents FCC Statement Important SafeguardsEnglish Preparation FeaturesPrecautions IntroductionMounting the lens Lens AdjustmentsLOW Voltage AC/DC Input Terminal Back focus adjustmentAC Mains Power Supply Electrical Connections Mounting the camera Operating controls and featuresFunction SET-UP AGC SpecificationsMTF Environmental Mechanical