Ricoh FV-L500B1 manual I/O Connector, Out

Page 4

1.2I/O Connector

￿HR10A7R6PB Hiroseor equivalent

￿This connector is for input /output signals.

￿Use HR10A7P6S (Hirose) or equivalent for the cab le side.

Pin Assignment

 

Pin No.

 

 

Signal Name

 

 

IN / OUT

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

Low Voltage

 

 

High Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

GND

 

IN

 

 

 

0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

I/O1

 

IN/OUT

 

IN

 

0 to +0.99V

 

+2.3 to +3.3V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

0V

 

+3.3V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

I/O2

 

OUT

 

OUT

 

0V

 

+3.3V

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

I/O3

 

OUT

 

OUT

 

0V

 

+3.3V

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

I/O4

 

OUT

 

OUT

 

0V

 

+3.3V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿Input/output signals can be assigned through the camera setting communication (see table 4).

￿Trigger input signal can be assigned either on Camera Link connector (CC1) or on the No. 2 pin of the IO connector through the camera setting communication.

IO Signal Patterns

 

 

 

Command No.

 

 

 

 

 

HR10A-7R-6PB (Hirose)

 

 

 

 

 

 

F0H[3..0]

 

 

No.2 Pin

 

No.3 Pin

 

No.4 Pin

 

No.5 Pin

 

 

 

 

 

I/O-1 (SP4)

 

 

I/O-2 (SP3)

 

 

I/O-3 (SP2)

 

 

I/O-4 (SP1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 0

 

0H

 

IN/TRG

 

N/A

 

N/A

 

OUT/TRG

 

(Initial Setting)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 1

 

1H

 

 

 

 

For Test Use Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 2

 

2H

 

OUT/CC4

 

OUT/CC3

 

OUT/CC”2

 

OUT/CC1

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 3

 

3H

 

OUT/FVAL

 

OUT/XSG

 

OUT/XSUB

 

OUT/CC1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 4

 

4H

 

 

 

 

 

 

 

OUT/

 

OUT/

 

 

 

 

 

 

OUT/FVAL

 

OUT/LVAL

 

Right Image Data

 

Left Image Data

 

 

 

 

 

 

 

 

 

 

 

 

(MSB)

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 5

 

5H

 

OUT/XHD

 

OUT/EXPDUR

 

OUT/TRG

 

OUT/CC1

 

 

 

 

 

 

(highactive)

 

(Exposure)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Option 6

 

6H

 

OUT/VD

 

N/A

 

N/A

 

OUT/HD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Others

 

7HFH

 

 

 

 

For Test Use Only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Output trigger signal has a latency of 30CLK (Approximately 470 nseconds) from input trigger signal.

Note 2: To input trigger signal from the I/O connector, change the setting of 12H.5.

Note 3: EXPDUR becomes high during exposure.

FVL500B1

4/31

User’s Guide Rev. 1.01

 

Image 4 Contents
FVL500B1 FVL500B1 User’s Guide RevTable of Contents Camera Link Connector Connector Camera Link ConnectorSDR 3M or equivalent Pin AssignmentI/O Connector / OUTEquivalent Circuit for the Input Pin of the I/O Connector +3.3V+3.3V On resister Max. = 30ohm 100ohm 10kohmNormal Mode Setting 10H Horizontal Timing CLK = 15.625 nsPartial Full Scanning Setting 10H 1XX01XXX, 11H Normal Full Scanning Setting 10H 1XX00XXX, 11HVertical Timing 10H 1XX01XXX, 11H 2.3 1/2 Partial Scanning2.4 1/4 Partial Scanning Variable Partial Scanning Setting 10H 1XX01XXX, 11H 2.5Binning Mode Setting 10H Horizontal Timing FVL500B1Setting 10H 1XX10XXX, 11H Setting 10H 1XX11XXX, 11HVertical Timing Binning Full Scanning Binning Partial Full ScanningBinning 1/4 Partial Scanning Setting 10H 1XX11XXX, 11H Binning 1/2 Partial Scanning Setting 10H 1XX11XXX, 11H= 30.063 μs, 54.890 Hz 2TAP12bit Data Order on the Camera Link Output2 Taps Transferring Image 2XE1Y ) Pixel Transferring ImageFrame Exposure Normal ModeElectric Shutter Pulse Width Trigger Mode Pulse Width Trigger Mode(VReset )Exposure Timing Pulse Width Trigger Mode NonReset30 CLK Edge Preset Trigger Mode Edge Preset Trigger Mode VResetEdge Preset Trigger Mode NonReset Reset Mode Communication Method Communication SettingsCommunication Format Start of Frame. Always set or receive the value as 02H Description of the format is as followsEnd of Frame. Always set or receive the value as 03H 【Example Code】Reading the data from the command 00H Command to send 02H, 00H, 00H, 01H, 00H, 03HCamera Control Command Camera Command List Eeprom25/31 Descriptions of the Camera Control Commands Underline settings are the factory default settings27/31 28/31 29/31 30/31 31/31