2. ADJUSTMENT

2-1. ADJUSTMENT CONDITION

1.Use the 5,100K viewer for the subject.

2.Set the trigger signal of oscilloscope to VIDEO OUT, and apply H sync unless specified.

3.Set S3001 (CA-3) to the all OFF position.

4.In adjustments without direction to display charts, shield light with a lens cap to provide dark condition.

5.Connect the video output to a video monitor with an input impedance of 75 .

6.Ground test point is TP200 (CA-2).

5,100 K viewer

CCD camera

H

L

CS mount surface

(H + h)2

L =x f – 12.5 mm H x h

L:Distance from CS mount to pattern (mm)

H:Pattern height (mm)

f : Lens focal length (standard 12 mm)

h: Height (4.8 mm) of CCD imaging surface

Note : The video monitor should be an under-scan TV.

2-2. PREPARATION

1.Install the adjustment software (VHJ-0157) in a computer running the Windows operating system.

2.Use the adjustment tool (VHJ-0127) to connect the camera to be adjusted to the serial port of the computer with RS- 232C cross cable, and then turn on the power for the com- puter and the camera.

3.Use COM1 serial port on the computer.

2-3. TABLE FOR SERVICING TOOLS

Ref. No.

Name

Part code

 

 

 

J-1

Color viewer

VJ8-0007

 

 

 

J-2

Adjustment jig

VHJ-0127

 

 

 

J-3

Calibration software

VHJ-0159

 

 

 

J-4

Chart for color adjustment

VJ8-0155

 

 

 

2-3-1. Computer screen during adjustment

 

 

 

 

 

 

 

 

 

ADJUSTMENT (VHJ_0159) Ver.1.00

 

 

 

 

x

 

SCHEDULE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rom Clear(Others Adj Value)

 

START

 

 

 

Adj.WhiteClip

 

 

 

 

 

 

 

 

 

 

 

 

Awb.Off(Manual White Balance)

 

 

NEXT

 

 

 

Agc Off(AutoIrisLens Adj)

 

 

 

 

 

 

 

 

 

 

 

 

 

Adj.Agc

 

 

STOP

 

 

 

Adj.Chroma

 

 

 

 

 

 

 

 

 

 

 

 

 

Wait Inkey

 

 

 

 

 

 

 

 

Adj.CCD White Defect Detection

 

+

 

 

 

 

 

 

 

 

 

 

 

 

STATUS

CLOSE

From 2-4. to 2-9. adjustments are continuous adjust- ment by adjustment software.

2-4. White Clip Adjustment

Adjustment location:

Measuring location: VIDEO OUT

Measuring equipment: Oscilloscope

Subject: No designation

Adjusting method:

1.Click the adjustment software installed from the personal computer, and the adjustment window will be displayed.

2.Click the start button. Rom clear to be white clip adjustment.

3.Display the viewer 2-10 sec at the edge of the screen.

4.Adjust (+) and (-) button so that the adjustment value is 830

±10 mVp-p.

2~10 sec

830 ± 10 mVp-p

VIDEO OUT

2-5. White Balance Adjustment

Adjustment location: VR302, VR303 (CA-3)

Measuring location: VIDEO OUT

Measuring equipment: Oscilloscope, Vectorscope

Subject: Color bar chart

Adjusting method:

1.Display the color bar chart at designated picture angle.

2.Click the “NEXT” button to be white balance adjustment.

3.Adjust VR302 and VR303 so that the luminescent spot rep- resenting white is overlapping with the crosshair mark in the center of the vectorscope.

– 3 –

Image 3
Contents Specifications Product Safety NoticeContents DISASSEMBLY, VR and TP Location and Board Location Table for Servicing Tools AdjustmentAdjustment Condition PreparationIris Level Adjustment Cabinet & Chassis Parts Accessories & Packing Materials9K JA 1/16W Electrical PartsCompl PWB,CA-1 Compl PWB,CA-2Transformer Flexible Flat Cables Compl PWB,CA-3Printed Wiring Boards P.W.B Overall WIRING, Block Diagram & Circuit DiagramsProduct Safety Notice CA-1 Overall WiringOverall Circuit Block Diagram IC101 Block Diagram ICX409AK IC102 Block Diagram CXD3400NVout AD9848A CA-1 CircuitTest Point Waveform Location CA-2 Circuit WaveformsT2521 CA-2 CircuitCA-2 Circuit UPPER-LEFT IC241 CA-2 Circuit UPPER-RIGHTCN211 CN241CA-2 Circuit LOWER-LEFT W2003 CA-2 Circuit LOWER-RIGHTPrinted Wiring Boards P.W.B C2257 CA-2 Board Side aTP200 CA-2 Board Side BJun./’03