Page 28

10 SPECIFICATIONS

GENERAL

• Frequency coverage

: 462.5625–467.7125 MHz

• No. of operating Ch.

: 14 (simplex)

• Mode

: 11K0F3E (FM)

• Frequency stability

: ±2.5 ppm

• Channel separation

: 25 kHz

Power supply requirement : 3 AA (R6) alkaline, BP-202, BC-149A

(negative ground)

or CP-18A

• Current drain

: Less than 500 mA

• Operating temp. range

: –4˚F to +122˚F; –20˚C to +50˚C

• No. of CTCSS freq.

: 38

• Dimensions

: 2116(W)4132(H)1116(D) in

(projections not included)

; 52.5(W)102.5(H)26.9(D) mm

• Weight

: 200 g; 7 oz (including 3AA (R6) batteries)

TRANSMITTER

• Output power

: Less than 500 mW ERP

• Maximum deviation

: ±2.5 kHz

• Spurious emissions

: Less than –40 dB

• Ext. mic. connector

: 3-conductor 2.5 (d) mm/2.2 k

RECEIVER

• Receiver system

: Double-conversion superheterodyne

• Sensitivity (12 dB SINAD)

: Less than 0.2 µV

• Selectivity

: More than 8.5 kHz/–6 dB

Spurious & image rejection: More than 40 dB

• Adjacent Ch. rejection

: More than 40 dB

Intermodulation rejection : More than 40 dB

• Audio output power

: More than 100 mW at 10 % distortion

(at 4.5 V DC)

with an 8 load

• Ext. speaker connector

: 3-conductor 3.5 (d) mm/8

All stated specifications are subject to change without notice or obligation.

22

Image 28
Contents I4088A Foreword Supplied Accessory Precaution Precaution Table of Contents Battery installation BP-202 Alkaline cellsPanel Description Switches, controls, keys and connectorsSpeaker Volume Control VOL PTT Switch PTTMode Switch Mode Channel UP Switch YKEY Lock Indicator Group Number IndicatorChannel Number Indicator 0TRANSMIT Indicator Appears during PTT onBattery caution Battery ChargingRecycling information U.S.A. only Charging connections Regular charging with the BC-149A, CP-18AIC-4088A BP-202 Turn the power OFF AC adapter AD-105 BC-119N Not usedAdjusting the volume Power onBasic Operation Selecting the operating channel Receive and Transmit Talk Range Group Mode Ctcss Setting the group codeCtcss code table FreqScan Function Starting the scanSmart-Ring Ring FunctionsCall-Ring Initial set mode Entering initial set modeOther Functions Voice scrambler functionTime-out timer Auto power OFF timerBeep tones ON/OFF Scan resume typeRing tone type LCD backlight‘ Auto power save Lock function‘ Resetting the transceiver ATS Automatic Transponder SystemPTT switch Lock switch Switch actionOptional HM-75A functions Specifications GeneralChannel frequency list Channel number and group numberCH Freq.MHz Options HM-46/HM-75A/HM-131 Speaker MicrophonesMemo 6274D-1US- w