Timing Diagrams
Figure B±4.The Relationship of Horizontal Drive Input and Video Output
HD (Input)
Active
Vedio
Video (Output)
(See B±1±8)
Figure B±5.Shutter Internal Mode
  | Integrate Frame  | 
  | Read Out Frame  | 
  | 
Shutter Command  | 525H  | 
  | 1050H  | 
  | 
  | 
  | 
  | 
  | |
(Input)  | 
  | 
  | 
  | 
  | 
Shutter Monitor²  | Integrate (Flex Timing)  | 
  | 
  | 
  | 
  | 
  | 
  | 
  | |
(Out)  | 
  | 
  | 3H  | 
  | 
Flush  | AB Capability High  | 
  | 
  | |
  | 
  | 
  | ||
Vertical SYNC  | 
  | 
  | 
  | 
  | 
(Internal)  | 
  | 
  | Read Out  | 
  | 
  | AB Capability Low  | 
  | 
  | |
  | 30H  | 1017H  | 3H  | |
  | 
  | |||
  | 
  | 
  | ||
  | Continuous  | Vertical  | 
  | Vertical  | 
  | Blank  | 
  | Blank  | |
  | 
  | 
  | 
AB Clock
34H
Shutter Window
Mechanical Shutter
or Strobe Light
Recomended Timing For High Dynamic Range XXXX Source Due to The Capability State.
Composite
Video (Out)
30H  | Read Out  | 3H  | 30H  | Read Out  | 3H  | |
1017H  | 1017H  | |||||
Vertical  | 
  | Vertical  | 
  | |||
  | 
  | 
  | 
  | |||
Blank  | 
  | 
  | Blank  | 
  | 
  | 
²Fall edge shows starting of CCD integration state. Rise edge shows AB capability state change. The integrate time does not change, but changes AB capability.